Mr. Bernard P. Orlan October 10, 2001 Indoor Air Quality Assessment Page 3 Stuyvesant H.S. (Manhattan) ATC Project No. 15-19125-0246

r SAMPLING RESULTS

Real-Time Ena ironmental Measurements

ATC collected one hundred-four (104) sets of real-time environmental measurements consisting of one hundred-two (102) in the school building and two (2) outdoors. These results are described below. Field data sheets are found in Attachment 1.

Temperature

Indoor dry bulb temperature measurements ranged from 67.4 °F to 78.1 °F. Measurements were within the range of 68 to 75 °F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). A few rooms on the 3rd and 51^ floors were slightly below the recommended range. The outdoor temperature range was 57 to 64.7°F.

Relative Humidity

The relative humidity indoors ranged from 28.2 percent to 46.8 percent. Most of the indoor measurements were within ASHRAE’s recommended range of 30 to 60 percent for occupant comfort. A few rooms on the 3rd and 5di floors were slightly below the recommended range. The outdoor relative humidity range was 26.8 to33.6 percent.

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 446 ppm to 2025 ppm. Three COg measurements were at or above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentration range was 373 to 395 ppm. Therefore, the acceptable level of COg at this location was 1095 ppm (background level + 700 ppm). Eight measurements were within 10% of the 1095 ppm level and twenty-three (23) exceeded 900 ppm. The highest level measured (2025 ppm) was in a fully occupied classroom (Room 429). Levels above the recommended maximum do not indicate a health risk. Carbon’dioxide measurements are used as an indicator of available outdoor air. The primary source of COg indoors is occupant respiration;

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors were 0 - Ippm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentration was also 0 - 1 ppm.

Respirable Particulates

Respirable particulate concentrations indoors ranged between 10 pg/m^ and 39 pg/m3 . The concentrations of all samples were below the NPAAQS/ASHRAE guideline of 50 pg/m^ (annual average concentration of particulate matter 10 micrometers or less in aerodynamic diameter). The outdoor respirable particulate concentration range was 20 to 30 pg/m^.

CITY_21MC100_003100061

NYC-WTC_000271059

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000271059Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000311687

Indoor air quality assessment conducted on October 9, 2001 at Stuyvesant High School.

Similar indexed content

Compare copies and versions →