ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 2-8-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 ■ Long Island .City, ’NY 11101. Report Date: 10/29/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected,-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Pinal Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No. :57a5^^2^ ■* Exterior & Interior of Building & Roof Date Received: 10/28/01 Grid Openings Analyzed:__ 4

Project Sample No.: 16 Average Grid Opening: 106.00 um

Air Volume: 1944 liters Total Area Analyzed: 0.0450-mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity : 22.2 .s/mm2 Effective Area: 385 mm2 0,0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct a=5um Struct/mm2 Struct/cc nqm/mS

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0. 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0• Non-Asbestos 0 0 0 0 0 c 0.0 0.0000 N/A No Identification. 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None.detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_OO3O99944

NYC-WTC_000270975

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270975Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270551

TEM asbestos analysis for exterior & interior of New Stuyvesant H.S.; includes sample numbers and date.

Similar indexed content

NYC-WTC_000270801

TEM asbestos analysis of New Stuyvesant High School, received 10/24/01.

Similar indexed content

NYC-WTC_000270258

TEM analysis of exterior facade at New Stuyvesant High School, 10/06/01.

Similar indexed content

Compare copies and versions →