TEM air analysis report, Oct 25 2001

Machine-extracted title · confidence 95%

Cover letter and results for transmission electron microscopy analysis of air samples from a high school on October 25, 2001.

NYC-WTC_000182589
Page image
Scanned page image, NYC-WTC_000182589
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island-City, NY 11101 Report Date: 10/25/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 57SB - 62156 Exterior & Interior of Building fc Roof Date Received: 10/24/01 Grid Openings Analyzed;__ 4

Project Sample No.: 20 Average Grid Opening: 106.00 um

Air Volume: 1936 liters Total Area Analyzed:Q;0450!mi2

Filter Type: MCE 25 mm diam,, Pore Size: 0.45 um Analytical Sensitivity: 22 ..2 s/mTn2 Effective Area: 385 fnm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >°5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos {includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0,. 0000 N/A

Totals {All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. {EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in’, compliance with the quality specified for the method.

Analyzed by: . Report ^Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_OO3O99769

NYC-WTC_000182589

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182589Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM air analysis report, Oct 23 2001

NYC-WTC_000182586

Cover letter and results for transmission electron microscopy analysis of air samples from a high school on October 23, 2001.

Similar indexed content

Compare copies and versions →