NYC-WTC_000293649
TEM analysis including SAED/EDS; exterior/interior assessment at New Stuyvesant HS; sample 5725.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM analysis; exterior/interior, sample 20.
NYC-WTC_000270887OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: '10/27/01 ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Parc 763), Vol. 52, No'. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stuyvesant H.S.,? 34 5 Chambers St., NY, NY TEM Sample No.: 5775 - 62381 ' Exterior & Interior of Building & Roof Date Received: lC/26/^ Grid Openings Analyzed: 4
Project Sample No. •■.20 Average Grid Opening: 106.00 um
Air Volume:19521iter^ Total Area Analyzed: 0.0450 inm2
Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity :_22_^2_£ZH!!!!2. Effective Area: 385 mm2 0.Q044 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct; Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0,0000 0
Total asbestos {includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 c 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method.■ This laboratory is in compliance with the quality specified for the method.
Tlnalyzed by: Report Reviewed by:
Marek Peysakhov Michael A.Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003099850
NYC-WTC_000270887
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000293649
TEM analysis including SAED/EDS; exterior/interior assessment at New Stuyvesant HS; sample 5725.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294008
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270979
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293781
TEM analysis for New Stuyvesant H.S. exterior & interior; received 10/21/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270973
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188697
Document recording TEM analysis data for asbestos fibers in air samples from a NYC Board of Education building exterior and interior.
5 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188696
Laboratory report presenting transmission electron microscopy results for asbestos fibers collected during an inspection of a high school.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293820
TEM analysis of exterior/interior building samples; SAED/EDS; Received 10/22/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270877
TEM asbestos analysis; exterior/interior, sample 10.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270259
TEM analysis data for NSHS exterior received 10/06/01.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293494
TEM data including air volume and EDS for NSHS samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188704
Document recording transmission electron microscopy results for asbestos fiber identification in air samples from a high school building.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000293649
TEM analysis including SAED/EDS; exterior/interior assessment at New Stuyvesant HS; sample 5725.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294008
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270979
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293781
TEM analysis for New Stuyvesant H.S. exterior & interior; received 10/21/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270973
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188697
Document recording TEM analysis data for asbestos fibers in air samples from a NYC Board of Education building exterior and interior.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis including SAED/EDS; exterior/interior assessment at New Stuyvesant HS; sample 5725.
Similar indexed content
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
Similar indexed content
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
Similar indexed content
TEM analysis for New Stuyvesant H.S. exterior & interior; received 10/21/01.
Similar indexed content
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
Similar indexed content