NYC-WTC_000270872
TEM asbestos analysis, exterior & interior of building at New Stuyvesant HS.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis with SAED/EDS for New Stuyvesant HS building, Oct 2001.
NYC-WTC_000270709OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North 'accredited NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/23/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction ISAED} and Energy-Dispersive X-RAY Spectroscopy (EDS) .Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stuwesant H.S., 34S Chambers St., NY, WY TEM Sample No.; 5739 - 61940 Exterior & Interior of Building & Roof Dace Received: 10/22/^ Grid Openings Analyzed;__ 4
Project Sample No.: 5 Average Grid Opening: 106.00 urn
Air Volume:. 1936 liters Total Area Analyzed: 0.0450 mm2
Filter Type; MCE 25 mm diam., Pore Size: 0.45 um ' Analytical Sensitivity; 22.2 s/mm2 1 Effective Area: 3S5 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5uiTi StrucC/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0,0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Tinalysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC1OO_OO3O997O5
NYC-WTC_000270709
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270872
TEM asbestos analysis, exterior & interior of building at New Stuyvesant HS.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270718
Asbestos fiber analysis by TEM for New Stuyvesant High School, received 10/22/01.
5 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270359
TEM asbestos analysis on NSHS sample 10/11-09, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270662
TEM asbestos analysis by AHERA method; Project: New Stuyvesant HS, exterior/interior.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293864
TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270759
TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293859
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188712
Laboratory report detailing asbestos fiber analysis by transmission electron microscopy for air samples collected at a New York City Department of Education site in October 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270706
TEM analysis and diffraction/EDS data for exterior & interior of New Stuyvesant HS.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293855
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270545
TEM asbestos analysis with AHERA method for New Stuyvesant H.S.; lists sample numbers and date.
5 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270854
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270872
TEM asbestos analysis, exterior & interior of building at New Stuyvesant HS.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270718
Asbestos fiber analysis by TEM for New Stuyvesant High School, received 10/22/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270359
TEM asbestos analysis on NSHS sample 10/11-09, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270662
TEM asbestos analysis by AHERA method; Project: New Stuyvesant HS, exterior/interior.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293864
TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270759
TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis, exterior & interior of building at New Stuyvesant HS.
Similar indexed content
Asbestos fiber analysis by TEM for New Stuyvesant High School, received 10/22/01.
Similar indexed content
NYC-WTC_000270359
TEM asbestos analysis on NSHS sample 10/11-09, Oct 2001.
Similar indexed content
NYC-WTC_000270662
TEM asbestos analysis by AHERA method; Project: New Stuyvesant HS, exterior/interior.
Similar indexed content
TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.
Similar indexed content