NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/24/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Pinal Rule, EPA Federal Register (40 CFR, Part 763), Vol 52, No. 210, October 30, 1967
Sample Identification Analysis Parameters
?roject/Site; New Stuwesant H.5., 345 Chambers St,,. NY, NY T2M Sample No. .- 5748 62060
Exterior & Interior of Building & Roof
Date Received: 10/23/01 Grid Openings Analyzed:__ 4
Project Sample No.;_6 Average Grid Opening: 106.00 urn
Air Volutne : 1936 1it£^ Total Area Analyzed: 0.0450 Tnm2
Filter Type: MCE 25 mm diam., Pore Size: Q.45 urn Analytical Sensitivity;22 r s/m^
Effective Area: 385mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ngm/mS
Chrysotile Asbestos 0 0 0 0 c 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Anbiguous 0 0 0 0 C 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) c 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 c 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals {All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CITY_21MC100_003082552
NYC-WTC_000293855
OCR can misread numbers and units. Confirm readings against the page image before using them.