ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. .State ELAP #1087'9 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island. City, NY 11101 Report Date: 10/21/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEN) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysisparameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5735 - 61725 Various Sites Inside and Outside the Building Date Received: 10/20/01 Grid Openings Analyzed;__ 4

Project Sample No.: 11 Average Grid Opening: 106.00 urn

Air Volume :],928 ]J,t^rs Total Area Analyzed: 0.0450 mm2

Filter Type; MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity:22;^s/inm2 Effective Area; 385 mm2 0.0044 s/ce

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles 'Clusters Struct. Strucc > = 5uin SLruct/m[n2 Struct/cc nqm/mS

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos •0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0,0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 . N/A No Identification 0 0 0 0 0 0 0.0 0.0000. N/A

Totals (All Structures) 0 0 0.0 o.oooc N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099615

NYC-WTC_000270628

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270628Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270593

TEM-based asbestos analysis with SAED/EDS for air samples at New Stuyvesant High School.

Similar indexed content

NYC-WTC_000293905

Asbestos fiber TEM analysis for New Stuyvesant High School exterior/interior samples; includes SAED/EDS identifications.

Similar indexed content

NYC-WTC_000294007

TEM analysis report for New Stuyvesant H.S. site, Oct 2001.

Similar indexed content

Compare copies and versions →