NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 31%

TEM analysis report for New Stuyvesant H.S. site, Oct 2001.

NYC-WTC_000294007
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/28/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM} With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, ERA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification AnaiysisPar^met^i^

Project/Site: New Stuyvesant H.S, 345 Chambers St., NY, NY TEM Sample No.: 5784 62388 Exterior & Interior of Building & Roof Date Received :l 0227/01 Grid Openings TUrialyzed:__ 4

Project Sample No. Average Grid Opening: 106,00 urn

Air Volume : 1936 iiters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity; 22.2 5/mm2 Effective Area: 385mn^ 0■0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed concentratiot Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct •=5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 c 0 0 0.0 0.oooc 0

Amphibole Asbestos 0 0 0 c 0 0 0,0 0.oooc 0

Ambiguous 0 0 0 c 0 0 0.0 o.oooc 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0 . OOOC 0 Non-Asbestos 0 0 0 c 0 0 0.0 0.oooc N/A No Identification 0 0 0 0 0 0 0.0 O.OOOC N/A

Totals (All Structures) 0 0 0.0 0.OOOC N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEN method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082728

NYC-WTC_000294007

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000294007Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000294022

TEM-based asbestos identification and SAED/EDS for exterior & interior samples at New Stuyvesant H.S.

Similar indexed content

NYC-WTC_000293897

TEM and SAED/EDS analysis for exterior/interior of building; sample 5758.

Similar indexed content

NYC-WTC_000293905

Asbestos fiber TEM analysis for New Stuyvesant High School exterior/interior samples; includes SAED/EDS identifications.

Similar indexed content

NYC-WTC_000294023

TEM analysis of asbestos fibers from New Stuyvesant High School project samples.

Similar indexed content

NYC-WTC_000292748

TEM asbestos analysis report with SAED/EDS for New Stuyvesant High School, Oct 29, 2001.

Similar indexed content

Compare copies and versions →