Asbestos TEM analysis, New Stuyvesant HS, Oct 1987

Machine-extracted title · confidence 34%

TEM asbestos analysis with SAED/EDS for exterior & interior of New Stuyvesant High School, received 10/09/01.

NYC-WTC_000270306
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. , 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 . Long Island City, NY 11101 Report Date: 10/09/01

ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: TkHERA Final Rule, E?A Federal Register (40 CFR, Part 763), Vol, 52, No. 210, October 30, 1987

Sample Identification Analysis Parametiers

Project/Site•. New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5649 - 60683 Exterior & Interior of Building & Roof Date Received: 10/09m Grid Openings Analyzed:__ 4

Project Sample No.: NSHS-EIR-10/9-06 Average Grid Opening: 106.00 um

Air Volume: 1899 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity :22;2 s/rnrn2 Effective Area: 385 mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct, Filter Air Fibers Bundles Clusters Struct. Struct > = 5uni Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 .0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

C ITY_2 IMC10y_0 0’3 0 9 9 28 8

NYC-WTC_000270306

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270306Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293420

Asbestos TEM analysis with SAED/EDS for New Stuyvesant HS site, 10/09/01.

Similar indexed content

NYC-WTC_000188631

Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.

Similar indexed content

Compare copies and versions →