NEW YORK CITY DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF WASTEWATER TREATMENT

UMITATIONS FOR EFFLUENT DISCHARGE TO SANITARY OR COMBINED SEWERS

Project Name/Location WTC - South Projection Date: January 2,2001

Sample Treatment Paratneter Limitations Units Note Results * Over / Under Required

Temperature <150 not measured

Total Petroleum Hydrocarbons 50 ppm 19.2 NO

£y. 5-11 SU’S 8.09 NO

Cadmium 2 ppm Daily Avg. 0.69 ppm <0.05 NO

Chromium (total) 5 PP"’ <0.05 NO

Copper 5 ppm <0.05 NO

Lead 2 PP"’ <0.05 NO

Mercury 0.05 PP'b <0.002 NO

Nickel 3 ppm <0.05 NO

Zinc 5 ppm <0.05 NO

Flash Point >140 DegF >140 NO

Benzene 134 PPb Method 602 <5 NO

Ethylbenzene 380 ppp Method 602 <5 NO

Toluene 74 PPP Method 602 8 NO

Xylenes 74 ppp Method 602 <5 NO EPA method 608 only with PBC’s (total) 1000 PPt MDL = 65 ppt All below Detection Limit of 65 ppb

Total Suspended Solids No Limit 17 NO

Tetrachloroethylene 164 ppb <5 NO

MTBE 10 ppb 65 55 YES

Napthalene 47 ppp <5 No

Other PPP

‘ Indicate test data origin Independent Testing Labs - College Point, NY - sample collected 12/13A31

Grab sample from pump discharge

•* Analysis for PCB's are required ONLY if BOTH conditions listed below are met: 1) if proposed discharge > 10,000 gpd 2) if duration of a discharge > 10 days

CITY_2IMCl0 0_0 00016784 NYC-WTC_000268813

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268813Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →