Bulk sample analysis report, DCAS HQ, 14-22 [address], Manhattan

Machine-extracted title · confidence 50%

Bulk analysis results for multiple floor samples from DCAS project at 14-22 [address] building.

NYC-WTC_000268394
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

t KAM CONSULTANTS 35-40 J6th Street Long Island City NewYorfc,11106 r Tel: (718)729-1957 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS; 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# I 2 4 3

Lab Sample ID# 010904A-116 010904A-117 0109O4A-118 010904A-119 010904A-120 Sample Location 6th Floor 6th Floor 6th Floor 5th Floor Sth Floor

HomogeneiPr' Yes Yes Yes Yes Yes Sample Description Exterior W indow Exterior W indov'. Exterior W indow Exterior W indo^'t Exterior Window Caulking Caulking Caulking Caulking Caulking

Color Gr Gr Gr Gr Gr Texture Non Fibrous Non Fibrous Non Fibrous Non Fibrous Non Fibrous Sample Treatment Acid Digestion Acid Digestion Acid Digestion Acid Digestion Acid Digestion & Ashing & Ashing & Ashing & Ashing & Ashing Asbestos Present (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat (Type & Percent) 0% 0% 0% 0% 0%

Non Fibr Mat (Percent) 100% 100% 100% 100% 100% Date Received. 9/4/01 Date of Analysts 9/5/01 Date of Report. 9/5/01

Analyst: M . IJ k? Lab Mana^: K Mark Ulanecki David Chen * Analysis of samples is performed bv Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments. Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement bv NVLAP or any agency of the US Government. NYS-DOH ELAP it 11273 NIST-NVLAP # 102047 A/HA #: 100269

1

CITY_21MC100_002784981

NYC-WTC_000268394

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268394Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →