NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Bulk sample analysis, City Hall, Oct 2001

Machine-extracted title · confidence 39%

Bulk sample analysis report for NYC-DCAS at City Hall; multiple Lab Sample IDs and locations.

NYC-WTC_000268202–000268204
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUANTS 35-40 36th Street Long Island City Mew York, 11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: CITVHALL NY, NY PROJECT#: Client Sample ID# 1 2 3 4 5 Lab Sample ID# : 010915A-726 010915A-727 010915A-728 010915A-729 010915A-730 N/E comer rm betw 3rd floor office 3rd flixir corridor 3rd floor corridor 3rd floor office 2ndA3rd floor North side North side West side Soutli West side

Homogeneity: Yes Yes Yes Yes Yes Sample Description wipe/desk wipe/desk wipe/table wipe/metal chest wipe/table

Color: Blk Blk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present; (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat (Type & Percent); 5%CELL 10%CELL 12%CELL 15%CELL 10%CELL

Non Fibr. Mat (Percent): 95% 90% 88% 85.00% 90% Date Received: 9/15/01 Date of Analysis: 9/15/01 Date of Rejxart: 9/16/01

Analyst: M ■ utn 1 Lab Manager: D. David Chen M. Ulanecki * Analysis of samples is performed bv Polarized Lieht Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coyerings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The resulis relate only to the items calibrated or tested. ♦ The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used bv the client to claim endorsement bv NVLAP or anv agency of the US Government, NYS-DOHELAPIt}I273 NIST-iWLAPO 102047 AIHA 100269

1

CITY_21MC100_006262404

NYC-WTC_000268202

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268202Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →