Bulk sample analysis, 49-51 [name], 2001

Machine-extracted title · confidence 49%

Bulk sample analysis report for DCAS project at 49-51 [name] with sample IDs and locations.

NYC-WTC_000268190–000268194
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCOMSUUANTS 3S-403«thStmt Long Island City IE it. k N8wYort.1tlO« Toi: (718)729-1997 Fax: (718)729-18711

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 49-51 Chamber Street PROJECT#: Client Sample ID# : 1 9 3 4 5 Lab Sample ID# : 010918C-984 010918C-985 0I0918C-986 010918C-987 010918C-988 Sample Location: Entrance Roof South Side West Staircase West Elevator Staircase E West Facing Roof to Roof Lobby East East 14th Floor 14th Floor 14th Floor

Homogeneity: Yes Yes Yes Yes Yes Sample Descripiion: Floor Floor F loot Floor Floor Wipe Wipe Wipe Wipe Wipe

Color: Blk Blk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type &. Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% c% 0% 0% Other Fibr, Mat (Type: & Percent): 10%CELL 8%CELL 8%CELL 5%CELL 8%CELL 5%SYNTH 3%SYNTH 5%SYNTH 3%SYNTH 3%SYNTH Non Fibr. Mat. (Percent): 85% 89% 87'% 92% 89% Date Received: 9/18/01 Date of Analysis: 9/18/01 Date of Report: 9/18/01

Analyst: Lab Manager: Rood’ ■ouis David Chen * Analysis of samples is performed Polarized Light Microsccpv fPLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Ster^binocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials, Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP #11273 NIST-NYLAP# 102047 AIHA #: 100269

1

CITY_21MC100_0 06262386

NYC-WTC_000268190

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268190Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →