Bulk sample analysis, NYC-DCAS, 111 [name] building

Machine-extracted title · confidence 49%

Bulk sample analysis report with multiple Lab Sample IDs and room designations.

NYC-WTC_000268155–000268156
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUOXHTS 3S-40 36th Street Long Island City NewYork,11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE AN/iLYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 111 Centre Street, Manhattan, New York PROJECT#: Client Sample ID# : 1 2 3 4 5 Lab Sample ID#; 011003A-144 011003A-145 011()03A-146 011003A-147 011003A-148 Sample Location: Room # 1242A Room # 1242A Room # 1242A Room # 322 Room # 322

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Window Sill Furniture A/C Ceiling Furniture Furniture Wipe Wipe Register Wipe Wipe Wipe

Color: Wh/Blk Wh'Rlk Wh/Blk Wh/Blk Wh/Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 10%SYNTH 3%CELL 10%SYNTH 2%SYNTH 5%SYNTH%SYNTI <1%FBGL 5%SYNTH 2“z8CELL <1%FBGL 3%CELL Non Fibr. Mat. (Percent): 89% 92% 88% 97% 92% Date Received: 10/3/01 Date of Analysis: 10/3/01 Date of Report: 10/3/01

Analyst: Lrib Manager: CV Roody Louis David Chen * Analysis of samples is performed b/ Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) / * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP # 11273 NIST-NVLAP# 102047 AIHA #: 100269

1

CITY_21MC100_006262314

NYC-WTC_000268155

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268155Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →