(jCT-01-2001 MON 01:52 PH NIOSH/R-11 FAX NO. 5134537147 P. 02

Comments on the WTC Emergency Site Health Monitoring and Sampling REP (lO/i/01)

], Recommend including a section detailing any required air monitoring in conjunction with a confined space entry program at the WTC site. This information could be included in the section entitled “Additional Site Monitoring Requirements”.

2. Recommend using NIOSH Method 7300 (sample analysis by inductively coupled plasma- atomic emission .spectroscopy) to sample for 27 different elements, including lead. This would provide more detailed information on exposures to airborne metals at the site.

3. NIOSH hits not collected any personal or area air samples for formaldehyde at the WTC site, so I am unaware of the rational behind this sampling proposal. However, if this sampling is to be conducted, I would suggest a more comprehensive analysis for a variety' of aldehyde.’, including acetaldehyde, fonnaldchyde, and furfural. The sampling collection a.ud analysis method would be similar to just measuring formaldehyde.

4. 1 would suggest eliminating the total dust/crystallinc silica analysis for the break area. ■Sampling for respirable dusi/crj'stalline silica would be sufficient.

5. 1 am unclear of the need for monitoring for BTEX since these same compounds (benzene, toluene, ethyl benzene, and xylene) can be included in the aromatic hydrocarbons analysis. I addition, 1 am unclear what tasks are included in the designation “Operators” for the BTEX monitoring (heavy equipment operators?).

6. Since concern over potential worker exposures to Freon, phosgene, and hydrogen sulfide have periodically arisen over the past several weeks, I would suggest expanding the WTC Sampling Requirements table shown at the end of the document to include as many of these .substances as possible. The sampling frequency could be “as needed” and include .some guidance on .sample collection (for example, colorimetric detector tubes).

CITY_21MC100_003572843

NYC-WTC_000267551

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000267551Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000317718

Comments on air monitoring for confined spaces at WTC site, Oct 2001 draft.

Similar indexed content

NYC-WTC_000407824

Comments on WTC site health monitoring and sampling plan, including air monitoring and analytical methods.

Similar indexed content

NYC-WTC_000407825

Tabulated sampling plan for workers and responders; targets metals, asbestos, and related exposures.

Similar indexed content

Compare copies and versions →