NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Scope of services for personal exposure monitoring, WTC

Machine-extracted title · confidence 58%

ATC scope of services for personal exposure monitoring at World Trade Center site.

NYC-WTC_000266925–000266928
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

samples. Filter cassetteJ^|^ll be taped over the top and bottom l^^ep the plugs on the end ' f Ihe cassette and to prevent sample tampering prior to analysis. • Charcoal Tubes - Charcoal tubes should be mailed in a cardboard box and adequately packaged to prevent breakage during shipment. Bulk solutions must never be shipped in the same package as charcoal tubes. • Bulk Samples Bulk samples shall be packaged in labeled containers compatible with the sample and tightly sealed to prevent leaks and spills. Some bulk samples may be considered as hazardous materials by the U.S. Department of Transportation and have special requirements for packaging, labeling, and method of shipment. Sampling Quality Persons conducting site monitoring shall have adequate training and/or experience commensurate with the type and complexity of the monitoring program. They should be able to understand the limitations of the equipment they use, proper methods of calibration, proper methods of sealing and shipping samples, and the importance of chain-ofeustody. Calibration data sheets, similar to Figure 3, will be used to document calibration and sample control.

All instruments shall be calibrated or checked for proper function in accordance with manufacturers specifications and before use for each shift, if appropriate. Instrument checks may be necessary during the day and al the end of use to confirm instalment accuracy. Duplicate readings may be taken to confirm individual instrument response. Air sampling pumps will be calibrated with primaiy standards (e.g., dry calibrator or bubble-tube method). Instalments shall be operated and maintained in accordance with the manufacturer’s specifications, fhe manufacturer’s operation and maintenance manual will be kept al the site work location for each type of instrument that is being used. Data Review ATC will assess and interpret monitoring data and results based on standard industry practices and professional judgment. All calculations performed on raw data (e.g., time-weighted-average calculations) shall be documented and reviewed by a certified industrial hygienist. BECHTEL reserves the right to reject data not meeting Data Quality Objectives at no cost to the project. BECHTEL reserves the right to audit the ATC's facility and procedures. Deficiencies between stated qualifications and audit results shall be corrected with no additional costs to BECHTEL. Electronic Data Management Sample and monitoring results for all data collected during the project will be maintained in a database that will be updated daily. ATC will maintain quality reviewed data electronically in accordance with Table 3. Weekly updates will be provided to BECHTEL for dissemination. Data collected under this contract will not be the property of ATC. ATC may not release any data, either preliminary or final, without the written approval of BECHTEL. The following definitions are provided for clarification of sample recording. Station Type: This field refers to the industrial hygiene sample collection. BULK is a sample collected by grab or field composite of solid materials (e.g., debris, dust, insulation, coatings). PERSONAL includes any sample collected on a worker with the intent of measuring the potential exposure of the single employee to a potential contaminant including breathing zone air samples and skin exposures. AREA samples are those samples collected in a 'work or break area to document any possible area wide exposure to contaminants that personnel in the area may be exposed; area samples may include air and dust fall samples. OTHER samples would include any physical parameter monitoring (e.g., noise sources, lighting levels, ambient weather conditions).

CITY_21MC1OO_OO8153382

NYC-WTC_000266927

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266927Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →