KAMCUNSUUANIb 35-40 3«hStfMt Long Island City NwYorlt,11106 Tel: (718)729-1997 Fax;{718)729-1875

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 280 Broadway, Manhattan, NY PROJECT#; Client Sample ID# 26 27 28 29 30 « Lab Sample ID# 0I0932B-1414 0I0922B-14I5 010922B-1416 010922B-1417 010922B-1418 Sample Location 6th Floor 6th Floor 6th Floor North/' 4th Floor 4th Floor Facing South North Window South Corridor South W'indow North W'indow Court Yard Window North Court Yard Window Homogeneity Yes Yes Yes Yes Yes Sample Description Window Sill Window Sill Window Sill Window Sill Window Sill W ipe W ipe Wipe W ipe W'lpe

Color BIk Blk BIk BIk Blk Texture Mixed Mixed Mixed Mixed Mixed

Sample Treatment None None None None None

Asbestos Present. (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat (Type & Percent). 2%SYNTH 5%SYNTH 3%CELL 5%CELL 2%CELL

Non Fibr Mat (Percent)' 98% 95% 97% 95% 98% Date Received: 9/22/01 Date of Analysis 9/23,01 Date of Report 9/24/01

Analyst; Lab Manager: 1 N'la^rk Ulanecki David Chen * Analysis of samples is perfori ;d bv Polarized Liaht Microicopv (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments. Ster^lobinocular microscope (MEIJI EMT-Serial # 25930). Polarized Light Microscope (MEIJI ML-POL-Serial # 1034) * PLM is not consistently reliable in detecting asbestos in flo tr coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used bv the client to claim endorsem :nt bv NVLAP or any agency of the US Government. i\YS-DOH ELAP if 11273 MST-N^LAP 102047 AIHA 200269

CITY_21MC100_002777788

NYC-WTC_000266430

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266430Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →