BULK SAMPLE A >JALYS1S REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: 60 Centre Street, Manhattan, N’'
PROJECT#:
Client Sample ID# : 16 17 18 19 20
Lab Sample ID# ; 010919B-1137 010919B-1138 010919B-1139 010919B-I140 010919B-1141
Sample Location Room 529 Room 531 Room 531 Room 518 Room 519
Window Sill Top of Desk Ceiling Vent Window Sill Top of Desk
E.xhaust
Homogeneity Yes Yes Yes Yes Yes
Sample Description Dust Dust Dust Dust Dust
Wipe Wipe Wipe Wipe Wipe
Color Blk Blk Blk Blk Blk
Texture Mixed Mixed Mixed Mixed Mixed
Sample Treatment. None None None None None
Asbestos Present;
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% 0% 0% 0%
Other Fibr Mat.
(Type & Percent): 2%CELL 3%SYNTH 10%SYNTH 5%SYNTH 65%SYNTH
Non Fibr Mat.
(Percent): 98% 97% 90% 95% 35%
Date Received; 9/19/01
Date of Analysis- 9/19/01
i2
Date of Report. 9/19/01
Analyse Lab Manager: 1 J_____________
Roodv Louis David Chen
* Analysis of samples is performed by Pojanzed Light Microscopy (PLM) - Point Counting Method
(EPA 600/M4-82-020)
* Analytical equipments- Stereobinocular microscope (MELI EMT-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated a. non-asbestos-containing
* Samples will be stored for ninety (90) days and then returred to the client upon request
* The results relate only to the items calibrated or tested.
♦ The certificate of report shall not be reproduced without th : written approval of the laboratory
* The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government
NYS-DOH ELAP # 11273 NIST-N^LAP » 102047 A/HA#: 100269
4
CITY_21MC1OO_OO2777727
NYC-WTC_000266375