Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 07/14/09
Floor Zip Borough Block Lot Squad # Badge #
Various 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU2068MN08 yes
Contractor's Name Sample Number
LVI Environmental
Address City Sample Number
462 Getty Avenue Clifton
State Zip Phone Sample Number
NJ 07011 973-772-3660
Third Party Air Monitor Owner's Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
state Zip Phone state Zip Phone
NY 10018 212-221-7822 NY (212)962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 7:00 pm to 8:45 pm
On arrival at the premise I met Victor Quizphi Project scientist of TRC.
We proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to
enter the regulated area on V* floor. Two workers were present for the decon maintenance, cleaning shower
chambers and organizing the clean room.
Negative air pressure on the floor was -0.035.
Based on LVI schedule activities include: finish tents prep at columns on 2"^ floor, check criticals and micro
traps on V* floor; scrape fireproofing, box out debris on Basement A floor.
V* Floor - 2 Asbestos Handlers were on the floor vacuuming the hole on the floor at the area #5 and sealing
the box. TRC representatives were inspecting the locations of the terrazzo floors inside the work area and 7
holes on the floor at the various locations, containing suspicious ACM material, to collect the samples for
laboratory analysis. I observed small black spots of the flashing material at the bottom of the cider block wall of
the north/west side wall and area #5; I took the photos. I observed also that exhaust duct at the north side
micro trap was broken. Handler Supervisor Victor was advised, and exhaust duct was repaired immediately.
Inspection was done on micro trap tents.
Using the entrance from the first floor I proceeded to the Basement A.
Basement - 18 Asbestos Handlers were inside the work area. Workers were on mezzanines cleaning and
washing the beam, resealing the critical; scraping the ceilings and beams; breaking down the brick cover of the
cider wall. Others were spraying the area with amended water, picking up debris, preparing boxes. 14 Gaylord
boxes were on the floor ready to be taken out. 12 micro trap machines were powered on and 3 on stand by.
Using exit I went back to the 1 floor decon.
After following the decontamination procedure I exited the work area.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2__________________
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queeiis 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP_WORBY_CANNATA_SUBP_000130983
NYC-WTC_000266041
OCR can misread numbers and units. Confirm readings against the page image before using them.