NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 01/16/09
Floor Zip Borough Block Lot Squad # Badge #
Various 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M Gagnidze F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 1001S NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 9:00 am to 10:10 am
I arrived at the premise at 9:00 am. LVI schedule informed that activities include Eagle -
erecting scaffolds to access deck, cleaning work area on 5*'’ floor, preparing North decon,
clear off floor, start demo on 3"^ floor, clear of floor, prepare for demo on the 2"“ and V' floors.
I proceeded to the decon, signed the log book, don the appropriate level of personal protective
equipment to enter the regulated area on 4*' floor. Negative air pressure on the floor was 0.041.
One worker was present for the decon maintenance.
Using B stairwell I went to the 5*" floor.
s'" Floor - 25 workers were observed on the floor, plasticizing the critical barriers across the work area,
using 2 scissor lifts, inspecting the electrical panel, erecting scaffolds on the east side of the work area,
wrapping and loading out boxes, moving the scissor lifts, preparing the area for cleaning;
wrapping electrical wires with poly.
5 Gaylord boxes were ready for load out. Inspection was done on micro trap machines and tents.
I used B stairwell to proceed to the 3'" floor.
3'“ Floor - 18 workers were working on the floor setting up exhaust ducts for the north side decon; workers
on two ladders were wrapping water hose, demolishing the wall, taking down frames and cutting using the
equipment with HEPA vacuum attached. Other workers were preparing, wrapping boxes, inspecting and
re-sealing the critical barrier, removing debris from the ground, loading out boxes through the waste decon
A large amount of poly wrapped beams and sealed 5 Gaylord boxes, which have been sprayed with
amended water, were at various locations on the floor ready for load out.
25 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents.
Using B stairwell I proceeded to the 2"“ floor.
2"“ Floor - 39 workers were found inside the work place cleaning off the floor, sealing the critical barriers,
wrapping electrical cables wit poly, removing the metal frames and cutting into pieces, using the power tool
attached to the HEPA vacuum, wrapping beams with poly, loading out boxes, removing metals from the
ceiling and the wall, cutting to the pieces, placing into the boxes and spraying with amended water.
Inspection was done on micro trap machines and tents. 35 Gaylord boxes and a large amount of poly
wrapped beams were ready to be taken out.
I used B stairwell to proceed to the V floor.
r‘ Floor - 8 workers were observed on the floor in the process of setting up exhaust ducts for micro
trap machines, wrapping water hose to prevent from frigid. Workers inside the electrical room were erecting
the frames and covering with poly the engine machine, preparing the work area for demo.
I used B stairwell to proceed to the 4“’ floor.
After following the decontamination procedure I signed the log book and used south hoist
to return to the ground floor.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough I -Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Rithmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No accestt 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP_WORBY_CANNATA_SUBP_000130857
NYC-WTC_000265976