Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 05/13/09 Floor Zip Borough Block Lot Squad # Badge # r' Fl, Bsmt 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU2068MN08 yes Contractor’s Name Sample Number LVI Environmental Services Inc. Address City Sample Number 462 Gerry Ave Clifton State Zip Phone Sample Number NJ 07011 (973) 772-3660 Third Party Air Monitor Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 (212)221-7822 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 4:45 pm to 7:30 pm

On arrival at the premise I met Stephen Pharai Senior Project Manager of TRC, Victor Quizphi and Manuel Giurgi Project Scientists of TRC at the TRC office. They informed me that there was a water leakage from the r* floor contaminated area to the Basement.

Victor Quizphi, Manuel Giurgi and I, joint by TRC Technician Garry Monts, went across the scene of the location in the Basement.

I observed puddle of water at the various location of the floor. Affected areas were sealed with red Danger Asbestos Hazard Caution tape. At the South/East corner of the coin vault 1 observed debris of fireproofing from the ceiling. Existing eight air monitoring pumps, located at the Entrance by Security Trailer, Center, S/E, N/E, Stairwell A, 2 pumps by Cellar A, Entrance to stairwell B and at the Building Entrance of the Basement, were running samples.

Based on the Chain of Custody, Laboratory analysis results of samples, taken from 7:37 am to 4:46 pm, confirmed negative to ACM.

Manuel Giurgi and Technician Garry Monts started setting up six new additional air monitoring pumps at the areas affected by the water leakage:

East side of the cellar A, 15’ of column H3; East side of cellar A, north/east of column F3 within 10’; Center of cellar A, within 13’ of service elevator; North/west side of cellar A, column C5 North side of cellar A, within 15’ of south/west corner of the coin vault; North side of cellar A within 10’ of south/east corner of the coin vault.

The photographs are enclosed.

I left the Basement to proceeded to the Floor decon. LVI schedule informed that activities include: Clear floor, demo & wrap metal, load out on V floor.

1 signed the log book, don the appropriate level of personal protective equipment to enter the regulated area on 1 “’floor. Two workers were present for the decon maintenance, organizing the clean room.

Negative air pressure was -0.044.

V* Floor - 30 Asbestos Handlers were present on the floor in shift. Workers were found at the various locations on the floor in the process of sweeping and vacuuming the floor using HEPA filtered vacuum equipment, picking up excess water using wet-dry shop HEPA vacuum, cleaning floor using rags and mops, drying off the work area.

CITY_DEP_WORBY_CANNATA_SUBP_000130711

NYC-WTC_000265915

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000265915Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →