Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 09/03/08 Floor Zip Borough Block Lot Squad# Badge # Various 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU0086MN08 No Contractor’s Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 1 f?'z;962-230C Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 9:50 pm to 10:50 pm

I arrived at the premise at 9:50 pm. LVI informed that scheduled activities include scrape, boxing debris on 12"’ floor and interior demolition, cutting metal on 11and 10*” floors, loading out boxes to ATC trailer. I entered the decon area, suit up, don respirator and entered containment on 12"’ floor. One worker was cleaning in the decontamination enclosure system.

12*'' Floor-Workers were cleaning the ceiling in the south side area of the floor, 2 workers were spraying with amended water, another 6 workers on east side of the area were scraping and cleaning vertical columns and beams. Additional workers were cleaning the floor and vacuuming up the water from the ceiling cleaning. 20 Gaylord boxes were ready for load out. Inspection was done on micro trap machines and micro trap tents, air monitoring pumps were on. 20 Micro trap machines were powered on and 5 were on stand by. I observed that the exhaust duct, connected to the Negative Pressure machine on the northeast side of the work area was cut off. The Handlers Supervisor was advised to conduct emergency repair, 2 workers performed the repair. I used B stairwell to proceed to the 11"* floor.

11'** Floor - 18 Workers were working on the floor. Piles of poly wrapped beams which have been sprayed with amended water were present in various areas of the floor. Four workers were on scaffolds removing the metal.ducts. Six workers were removing the floor tiles and another person was spraying area with amended water. 3 workers were found in the process of wrapping debris and preparing Gaylord boxes. 26 Gaylord boxes were ready to be taken out. Two workers were wrapping debris and placing into Gaylord boxes. 5 Gaylord boxes were still open and I observed that debris were dry. Worker was advised to spray debris with amended water. 20 micro trap machines were powered on and 5 were on stand by. Inspection was done on micro trap tents. I used B stairwell to proceed to the 10"’Floor. 10**" Floor - There were 14 workers on the floor in the process of demolishing and wrapping of debris. 2 workers were cutting metal ducts into smaller pieces for load out. Power tools have an operating HEPA vacuum attached during cutting. 2 other workers were removing electrical wires from the ceiling. 12 workers were observed preparing the boxes, wrapping debris and placing into 4 Gaylord boxes. One worker was spraying with amended water on the Gaylord boxes. 20 micro trap machines were powered on and 5 were on stand by. Inspection was done on micro trap tents, 5 Gaylord boxes were on the floor.ready to be taken out.

I used B stairwell to go back to the 12*’ Floor, proceeded to the decon, showered out and signed the log book. I used the north hoist to return to the ground floor and meet with Supervisor Ed from LVI Environmental and informed him of the 12**' floor exhaust duct damage and advised him to keep a close watch on the exhaust ducts. He immediately contacted the Handler Supervisor of the floor to confirm that the exhaust was repaired. NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor’s Initial _____ Borough 1 “Manhattan 2=Bronx 3-Brooklyn 4=Queens 5=Richiinond Building Type A >6 stories B <6 ,storie,s C single family D school E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued 3-Ny access 4-Project not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000130535

NYC-WTC_000265860

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000265860Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →