Asbestos inspection, 130 Liberty Street site

Machine-extracted title · confidence 46%

Asbestos inspection at 130 Liberty Street, Oct 2008, LMDC site.

NYC-WTC_000265858
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 10/31/08 Floor Zip Borough Block Lot Squad # Badge # Various 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU0086MN08 yes Contractor’s Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr, Proj. Mgr/TRC Environmental 5:00 pm to 6:10 pm

I arrived at the premise at 5:00 pm, LVI schedule informed that activities include cleaning on 16"’ floor - North vestibule. Final air testing as necessary - South Camp Bay - on 18*’ through 14*’ floors, decon preparation - North side - on IS* floor, clean work areas on H*" and 10'* floors.

I used north hoist to go to the 15'*' floor, proceed to the decon, suit up, don respirator, signed the log book and using stairs went to the 16*’ floor.

le’* Floor - 8 workers were on the floor outside the decon erecting scaffolds, preparing for ceiling cleaning inside the work area. One person was present for decon maintenance. 10 Gaylord boxes were ready to be taken out. Micro trap machines were powered on. Manometer indicated that negative air pressure inside the work area was 0.025. Using stairs I went to IS'” floor. is'* Floor - 7 workers were found on North side of the floor plasticizing frames, working with equipment to construct the decon, preparing area for cleaning. I used north hoist to proceed to 11'* floor. Two workers were present for the decon maintenance, cleaning the shower room Negative air pressure on the floor was 0.074. I signed the log book and entered containment. 11*’’ Floor - 30 workers were present on the floor. Workers on 5 scaffolds were cleaning the ceiling and columns of the area 2 and 3, spraying all area with amended water, sweeping and vacuuming the floor, using equipment with HEPA filters attached, cleaning beams and columns inside the shaft area, cleaning, vacuuming and polyethylene sheeting walker ducts, using HEPA filtered vacuum equipment, placing debris into the boxes and spraying with amended water, re-sealing critical barriers, lifting up electrical wires. Others were preparing and wrapping boxes. 5 Gaylord boxes were ready for load out. Inspection was done on micro trap machines and tents. I observed that 2 machines were shut down. Supervisor on the floor was advised to inspect and repair micro traps. I used ladder to proceed to 10*’ floor. io'* Floor - 28 workers were found on site, cleaning and vacuuming the floor, picking up water, using a wet-dry shop HEPA vacuum, inspecting the critical barriers, preparing, wrapping and loading out boxes. 4 Gaylord boxes were ready to be taken out. 20 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents. I used ladder to go back to 11*’ floor. After following the decontamination procedure I signed the log book and used north hoist to go back to the ground floor.

Inspection was done on ATC trailers.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor’s Initial

Borough l=Manhattan 2=Bronx /^Brooklyn 4=Queens 5=Richmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000130533

NYC-WTC_000265858

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000265858Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →