Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 10/30/08 Floor Zip Borough Block Lot Squad # Badge # Various_________ 10006 1 54 1 1 A062 . Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze_____ F TRU0086MN08 yes Contractor’s Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel J'aval, Sr. Proj. MgrZTRC Environmental 9:30 pm to 10:30 pm

I arrived at the premise at 9:30 pm. LVI schedule informed that activities include demo, box debris on 8*" and S'” floors.

I proceeded to the decon, don the appropriate level of personal protective equipment to enter the regulated area on 8'*' floor. Negative air pressure on the floor was 0.065.

8‘'’Floor - No activities or personnel observed on the floor. 20 micro trap machines were powered on and 5 on stand by. I used B stairwell to proceed to the T*” floor.

T'" Floor - No activities or personnel observed on the floor. 20 micro trap machines were powered on and 5 on stand by. I signed the log book and using B stairwell proceeded to the 6“’ floor.

6*'’ Floor - 18 workers were found on the floor. Workers were in a process of wrapping debris with poly, HEPA vacuuming and wet cleaning the area, cleaning the floor of critical barriers, cutting metals from the ceiling, removing floor tiles and spraying with amended water, removing debris from the floor and cleaning the areas, cutting metal into the pieces with electrical tools attached to HEPA vacuum, spraying Gaylord boxes and poly wrapped beams with amended water, preparing boxes, boxing debris. A large amount of poly wrapped beams existed on the floor. 5 Gaylord boxes were ready for load out. Inspection was done on micro trap machines and tents. Using B stairs I went to the 4"’ floor.

4"’ Floor - 22 workers were present on the floor. Workers on 2 scaffolds were removing pipes and metal from the ceiling; others were covering electrical panel with poly, cutting metal and spraying with amended water, sweeping and vacuuming the excessive water from the floor with equipment equipped with HEPA filters, re-sealing critical barriers, changing the filters of micro trap machines, picking up debris from the floor, preparing boxes. 5 Gaylord boxes were ready to be taken out. 20 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents.

I used B stairs to go back to the 8“’ floor, proceeded to the decon. After following the decontamination procedure I signed the log book and used north hoist to return to the ground floor.

Inspection was done on ATC trailers.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor's Initial

Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code I = Violation Issued 2=No Violation Issued 3^No access 4=Project not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000130532

NYC-WTC_000265857

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000265857Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →