NYC-WTC_000260365
ATC provides indoor air quality measurements for May 15, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC IAQ measurements collected June 12, 2002 at the referenced school.
NYC-WTC_000260549–000260552OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlari June 13,2002 Indoor Air Quali ty A.ssessment Page 3 H.S. for Leadership <fe Public Service tM8941 ATC Project No. 15-19125-0290 Real-Time Ej^/Irqnm£ntalMta§vheme^
ATC collected one hundred and forty (140) sets of real-time environmental measurements consisting of one hundred and twenty-eight (128) in the school building and twelve (12) outdoors. All fourteen floors of the school were surveyed. Field data sheets are found in the Attachment. Readings were collected in the morning and evening. The results are described below.
Temperature
Indoor dry bulb temjserature measurements ranged from 76.0 to 82.8 °F. Forty-three (43) of the indoor measurements for temperature were above and none of the measurements were below the range of 7.3 to79 °F (at 50 percent relative humidity) recommended by ASHRAE Standard 55- 1992 during the summer season. The outdoor temperature ranged from 83.4 to 89.4 °F.
Relative Humidity
The relative humidity indoors ranged from 41.8 percent to 50.3 percent. All of the indoor measurements for relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity range was 56.4 to 66.3 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 661 ppm to 1013 ppm. All of the indoor measurements for CO; were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CTL concentration was 601 ppm. Therefore, the maximum acceptable level of COj at this location was 1301 ppm (background level + 700 ppm). Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO; indoors is occupant respiration.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors ranged from 1 ppm to 2 ppm. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations ranged from 1 ppm to 3 ppm.
Respirable Particulai'es (PM2,s)
Respirable particulate concentrations* indoors ranged between 26 pg/m’ to 36 pg/m’ with an average 29 pg/m’ None of the indoor measurements for PMj j were above the NPAAQS of 65 pg/m’ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m’ for sensitive individuals such as asthmatic people and children. The outdoor respirable particulate concentrations ranged from 134 pg/m’to 179 pg/m’ with an average of 156 pg/m’.
CONFIDENTIAL, CITY_21MC100_003464642 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000260551
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000260365
ATC provides indoor air quality measurements for May 15, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410923
Indoor air quality measurements and BOE coordination for H.S. for Leadership, June 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260451
Indoor air quality measurements taken May 22, 2002 for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410939
Documentation of accreditation scope for bulk asbestos analysis at ATC lab.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292000
ATC IAQ measurements collected June 14, 2002 for the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000291892
lAQ measurements at HS Leadership, 90 Trinity Place, May 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260545
ATC IAQ measurements collected June 11, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410919
Indoor air quality measurements conducted at the High School for Leadership & [name], June 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410931
IWQ measurements and narrative for H.S. Leadership project, June 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188377
Memo reporting indoor air quality measurements collected at a school on May 17, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260537
ATC IAQ measurements collected June 7, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000291976
ATC IAQ measurements conducted June 4, 2002 for BOE at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000260525
ATC IAQ measurements collected June 4, 2002 at the referenced school.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260537
ATC IAQ measurements collected June 7, 2002 at the referenced school.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000372057
ATC IAQ measurements at PS 234M reported to BOE; May 29, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260541
ATC IAQ measurements collected June 10, 2002 at the referenced school.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260545
ATC IAQ measurements collected June 11, 2002 at the referenced school.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260325
ATC report of IAQ measurements taken May 10, 2002 at the referenced school.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
ATC provides indoor air quality measurements for May 15, 2002 at the referenced school.
Similar indexed content
Indoor air quality measurements and BOE coordination for H.S. for Leadership, June 2002.
Similar indexed content
Indoor air quality measurements taken May 22, 2002 for BOE.
Similar indexed content
NYC-WTC_000410939
Documentation of accreditation scope for bulk asbestos analysis at ATC lab.
Similar indexed content
ATC IAQ measurements collected June 14, 2002 for the referenced school.
Similar indexed content