Mr. Bernard P. Orlan March 25, 2002 Indoor Air Quality Assessment Page 4 H.S. for Leadership & Public Service (M894) ATC Project No. 15-19125-0290

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.

jyOCQjncen tr^.on

The TVOCs conc:entrations were 0 ppm inside the building. These concentrations were below the AIHA guideline for odor control of 1 ppm. The outdoor TVOC concentration was also 0 ppm.

OIJSERV'ATIONS

During this assessment, ATC noted the following: • The interior of the building appeared clean and free of dust and debris; • The building wa.s occupied at the time of the assessment; • No smoke odor was detected in the building;

FINDINGS

Based on the real-time measurements, the following findings are presented;

1. Concentrations, of respirable particulates, CO, CO2 and TVOCs were below applicable standards and guidelines. 2. Seventeen (17) indoor measurement for temperature were above and two (2) measurements were belou the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 3. One hundred and fifteen (115) of the indoor measurements for relative humidity were below the ASHRJfE-iecommended range of 30 to 60 percent for occupant comfort.

It is our pleasure i:o provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 336 or 212.

Sincerely, Reviewed by: A TC ASSOCIA TES INC.

James R. Cohn, CIH, CSP Senior I\j»ject Manager Regional Manager Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003463772 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000260055

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000260055Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000370553

ATC reports IAQ measurements taken March 22, 2002 at High School for Leadership & [name].

Similar indexed content

NYC-WTC_000399272

May 2002 IAQ measurements at High School for Leadership & Space; BOE requested assessment.

Similar indexed content

NYC-WTC_000399254

Indoor air quality report dated May 7, 2002 for High School project; ATC.

Similar indexed content

Compare copies and versions →