NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
REPORT DATE: 03-04-02
CLIENT: NYC BOE
PROJECT ADDRESS: H.S. of Economic & Finance/100 Trinity Place
NY, NY
PROJECT NO: 41617-0563
SAMPLED BY: Chacko Mathew
SAMPLE DATE: 03-02-02
DATE RECEIVED: 03-02-02
DATE ANALYZED: 03-02-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(ug/fV)
01 9704 Floor First Floor Lobby by Aud. Entrance <9.0 9.0
02 9704 Sth Floor Cafeteria by Wall 2 Floor <9.0 9.0
03 9704 Auditorium by Wall 4 Floor <9.0 9.0
04 9704 Floor Classroom 406 Center Area <9.0 9.0
05 9704 Floor Classroom 304 Floor <9.8 9.8
06 9704 3rd Floor Hallway Floor <9.0 9.0
07 9704 5th Floor Hallway by Double Door Floor <9.0 9.0
08 9704 7th Floor Hallway Floor <9.0 9.0
09 9704 9th Floor Hallway Floor <9.0 9.0
10 9704 Cafeteria Wall 2 Window Sill 3.5 2.3
11 9704 Blank <9.0 ng 9.0 ng
NOTE 1:
THE REPORTING LIMIT (RL) IS 18.0 pg
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 pg/fF, Window sills 250 pg/fF,
Window wells 400 pg/ft\ Exterior surfaces 800 pg'fF.
NOTE 3:
Blank units are in pg
CONFIDENTIAL, CITY_21MC100_003463278
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000259748
OCR can misread numbers and units. Confirm readings against the page image before using them.