NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Wipe sample TEM report, BOE School for Leadership

Machine-extracted title · confidence 45%

Wipe sample TEM analysis report for BOE School for Leadership, Jan 2002.

NYC-WTC_000257112–000257114
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr Bernard P. Orlan January 25, 2002 Wipe Samples for Dioxins Pagel H S for Leadership & Public Service ('894M) ATCProiectNo 15-19125-0290

Combustion of PCB-contammg oils, such as during an electrical transformer fire, is known to produce dioxins. Burning of some plastics may also produce dioxins Dioxins are toxic and are considered to be carcinogenic

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^} The New York State Department of Environmental Conservation (NYSDEC) has set 0 0006 parts per million (ppm) as the allowable concentration of dioxin m soil. The EPA has established a residential clean-up goal of 1 part per billion (ppb)

WIPE SAMPLING RESULTS

ATC submitted nine (9) wipe samples for PCDDs/PCDFs (plus one blank) to Pace for analysis. A copy of the laboratory report is provided in Attachment 1 Samples were taken from areas specified by the parents association consultant The sample area was one square meter (m^). The sample locations and the areas are shown in the table as well as the results

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxm (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor This provides a single value (in nanograms) for the analytical results for each sample A copy of the analytical laboratory report is attached.

DIOXIN WIPE SAMPLE RESULTS (2, 3, 7, 8 TCDD EQUIVALENTS)

Cafetena Serving Window/DXl 0,017

Library table - north/DX2 0 040

Room 1106 floor - south/DX3 0.017

Room 903 floor - north/DX4 0.014 Room 715 floor - south/DX5 0.00053 Room 503 floor - north/DX6 0 0047 Hallway 3’’d floor - south/DX7 0.0011 Main Lobby - floor/DX8 0 062 Field Blank/DX9 0 00019

The concentrations on indoor surfaces ranged from 0.00053 to 0 062 nanograms per square meter (ng/m2). The levels found m all of these samples are below the NYSDOH guideline of 25 ng/m2.

CONFIDENTIAL, CITY_21MC100_003459565

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000257113

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000257113Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.