z KAM CONSULTANTS Z

o 35-40 36th Street o

Itano. co g Long Island City REPORT OF AIR MONITORING I o New York, 11106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) “0 o Tel: (718)729-1997 c o CT o Fax:(718)729-1876 CLIENT: DCAS DATE; 09/29/01 o' ro Oi PROJECT: ADDRESS: 100 Centre Street, Manhattan "0 17th, 14th, 7th, Sth, & Main Floor o 03 R W CLIENT FLOW FLOW SAMPLE FIBERS FIBERS E O TIME TIME O SAMPLE LOCATION BEF. AFTER VOLUME PER PER REMARKS LAB ID# o S R IN OUT CC o ID# (Ipm) (Ipm) (liters) FIELD c P K 3 01 17th Floor - By Stairs A Exit___________________ 11:02 2:02 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A010930A-01 Q 3 02 17th Floor - by Freight Elevat__________________ 11:04 2:04 10 JO 1800 <0055 <0.01 Air Quality (Immed. TAT) A010930A-02 03 17th Floor - Library West______________________ 11:06 2:06 JO. 10 1800 0.070 <0.01 Air Quality (Immed. TAT) A010930A-03 04 17th Floor - Library East______________________ 11:08 ZOS 10 10 1800 <0055 <0.01 Air Quality (Immed. TAT) A010930A-04 17th Floor - By Room 1732____________________ 11:10 2:10 10 10 1800 0.060 <0.01 Air Quality (Immed. TAT) A010930A-05 14th Floor - South Elevators Lobby_____________ 12:01 3)01 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A010930A-06 14th Floor - By Freight Elevator________________ 12:02 3)02 10 10 1800 0.090 <0.01 Air Quality (Immed. TAT) A010930A-07 14th Floor - Stairs A Exit______________________ 12:03 3)03 10 10 1800 <0055 <0.01 Air Quality (Immed. TAT) A010930A-08 09 14th Floor - Elevator Lobby North______________ 12:04 3:04 JO 10 0.070 <0.01 Air Quality (Immed. TAT) A010930A-09 10 7th Floor - Corridor North Side_________________ 12:30 3:30 JO. 10 JISOO <0.055 <0.01 Air Quality (Immed. TAT) A01O93OA-1O 11 7th Floor - Room 730 12:31 3:31 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A010930A-11 12 7th Floor - Stairs C Exit 12:32 3:32 10 10 1800 0.060 <0.01 Air Quality (Immed. TAT) A010930A-12 13 7th Floor - Stairs D Exit_______________________ 12:35 3:35 10 JO 1800 <0.055 <0.01 Air Quality (Immed. TAT) A010930A-13 J£ 7th Floor - South Elevator Lobby_______________ 12:36 3:36 10 10 1800 0.070 <0.01 Air Quality (Immed. TAT) A010930A-14 15 Sth Floor - Stairs D Exit_______________________ 12:45 3:45 10 10 1800 0.060 <0.01 Air Quality (Immed. TAT) A010930A-15 16 Sth Floor - By Freight Elevator_________________ 12:47 3)47 10 10 1800 0.100 <0.01 Air Quality (Immed. TAT) A010930A-16 17 Sth Floor - Corridor By Public Phones___________ 12:49 3:49 10 10 1800 0.080 <0.01 Air Quality (Immed. TAT) AO10930A-17 18 Sth Floor - By Stairs B Exit____________________ 12:50 3)50 10 JO 1800 <0.055 <0.01 Air Quality (Immed. TAT) A010930A-18 19 Sth Floor- By Room 502_______________________ 12:52 3)52 10 10 1800 0.060 <0.01 Air Quality (Immed. TAT) A010930A-19 20 Main Lobby - In Room 150____________________ 1:00 4:00 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A010930A-20 21 Main Lobby - South Entrance Centre Street Lobby 1:02 4:02 10 10 1800 0.090 <0.01 Air Quality (Immed. TAT) A010930A-21 22 Main Lobby - Middle Lobby Reception Desk_____ 1:04 4:04 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A010930A-22 23 Main Lobby - Baxter Street, Exit Lobby 1:06 4:06 10 10 1800 0.080 <0.01 Air Quality (Immed. TAT) A010930A-23

TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C. 4 = OTHER (SPECIFY): TYPE OF WORK: 1= BLDG DECON. 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING, 6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY): O SAMPLING TECHNICIAN: Z.B Nowak / M, Tctiatchueng DATE RECEIVED: 09/30/01 ROTAMETER: KAM- 04 DATE OF ANALYSIS: 09/30/01 l"^

o Analyst: \ Roody Louis DATE OF REPORT: 10/01/01 Lab Manager: 7^ David Chen The samples listed above are analyze^y Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area. O O KAM CONSULTANTS shall not be lipBle for information arising from samples that are not in its QA and QC program. I The results relate only to the itejn^alibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory. o The report must not be usedoy the client to claim endorsement by NVLAP or any agency of the U.S. Government. CO NYS-DOH ELAP #11273 AIHA # 100269 1 cn o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251717Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000178208

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178188

Laboratory report from KAM Consultants detailing phase contrast microscopy results of air filters collected for DCAS.

Similar indexed content

Compare copies and versions →