Air monitoring report, phase contrast microscopy, 9/26/01

Machine-extracted title · confidence 66%

KAM Consultants report of air monitoring for DCAS with phase contrast microscopy, dated 09/26/01.

NYC-WTC_000251689–000251692
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z z KAM CONSULTANTS o 35-4036thStreet o co

§ Long Island City REPORT OF AIR MONITORING c o o ro New York, 11106 Tel: (718 729-1997 Fax: (718 729-1876 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) CLIENT: DCAS DATE: 09/26/01 “0 c CT o' tn PROJECT: ADDRESS: 2 Laffayette, Manhattan "0 o o> 22nd Floor, 16th Floor, 12th Floor, Sth Floor,4th Floor, & Main Lobby co CD o R W CLIENT FLOW FLOW SAMPLE FIBERS FIBERS 0 E O TIME TIME O SAMPLE LOCATION BEF. AFTER VOLUME PER PER REMARKS LAB ID# S R IN OUT O ID# (Ipm) (Ipm) (liters) FIELD CC c P K 3 01 22nd Floor - Corner Corridor Day Care By Elevators 18:00 20:00 10 1200 A010927C-01 o JO. <0.055 <0.01 Air Quality (Immed. TAT) 3 02 22nd Floor - Stairway Y________________________ 18:02 20:02 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A010927C-02 03 22nd Floor - By Pantry_________________________ 18:04 20:04 10 JO. 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A010927C-03 04 22nd Floor - By Stairwell W_____________________ 18:06 20:06 10 JO. 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-04 05 22nd Floor - A/C Room 18:07 20:07 10 JO. 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-05 06 16th Floor - Corridor by Control Room____________ 18:28 20:28 JO 10 1200 0.070 <0.01 Air Quality (Immed. TAT) A010927C-06 07 16th Floor - Stairway Y_________________________ 18:30 20:30 JO JO. 1200 0.060 < 0.01 Air Quality (Immed. TAT) A010927C-07 08 16th Floor - Stairway W________________________ 18:32 20:32 10 JO. 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-08 09 16th Floor - A/C Room 18:34 20:34 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A010927C-09 10 12th Floor - Elevator Lobby_____________________ 18:45 20:45 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-10 11 12th Floor-Stairwell Y 18:46 20:46 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-11 12 12th Floor - Corridor by Stairs W_________________ 18:48 20:48 JO. 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-12 13 12th Floor - In A/C Room 18:50 20:50 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-13 14 Sth Floor - Elevator Lobby______________________ 19:10 21:10 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A010927C-14 15 Sth Floor - Corridor by Mens Restroom___________ 19:12 21:12 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-15 16 4th Floor - Corridor by Mens Bathroom____________ 19:22 21:22 10 JO 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-16 17 4th Floor - By Elevator Lobby____________________ 19:24 21:24 JO JO. 1200 0.060 <0.01 Air Quality (Immed. TAT) A010927C-17 18 4th Floor - By Main Entrance____________________ 19:26 2T.26 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-18 19 Main Lobby - Elevator Lobby____________________ 19:40 21:40 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-19 20 Main Lobby - By Main Entrance__________________ 19:41 21:41 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-20 21 Field Blank <0.055 A010927C-21 22 Field Blank <0.055 A010927C-22

TYPE OF RESPIRATORS; 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY): TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING, 6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY): o SAMPLING TECHNICIAN: Z.B Nowak / M. Golembo/M.Tchatchueng DATE RECEIVED: 09/27/01 ROTAMETER. KAM- 04 DATE OF ANALYSIS: 09/27/01 DATE OF REPORT: 09/27/01 to Analyst: Lab Manager: Deepak Bajracharya David Chen Q The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area. o o KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program. I The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory. o The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. co NrS-DOHELAP# 11273 AIHA # 100269 co 1 US co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251690Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000178237

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

Compare copies and versions →