Z Z KAM CONSULTANTS o 35-40 36th Street o co

Itano. g Long Island City REPORT OF AIR MONITORING I o NewYorM1106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) “0 o Tel: (718 729-1997 c o CT o CLIENT: DCAS DATE: 10/05/01 ro Fax: (718 729-1876 o' Oi PROJECT; ADDRESS: 111 Centre Street, Manhattan, NY "0 o CD R W CLIENT FLOW FLOW SAMPLE FIBERS FIBERS 0 E O TIME TIME LAB ID# SAMPLE LOCATION BEF. AFTER VOLUME PER PER REMARKS o S R IN OUT o ID# (Ipm) (Ipm) (liters) FIELD CC c P K 3 01 Room 118 Public Area _________ 12:25 14:35 10 10 2^ <0055 <0.01 Air Quality A011005U-01 o 3 02 Room 1167 Court Reporters_______ 12:33 14:40 10 10 1270 0.070 < 0.01 Air Quality A011005U-02 03 Room 927 Asst, Chief Clerk_______ 2:36 14:45 JO 10 1290 0.065 < 0.01 Air Quality A011005U-03 04 Room 837 Computers____________ 12:42 14:50 JO. JO. 2280 <0.055 < 0.01 Air Quality A011005U-04 05 7th Floor North/West Public Hallway 12:50 14:55 10 10 1250 0.070 < 0.01 Air Quality A011005U-05 06 Room 659 Judge________________ 12:55 15:02 10 10 1270 0.060 < 0.01 Air Quality A011005U-06 07 Room 488______________________ 13:04 25205 10 JO 1210 <0.055 < 0.01 Air Quality A011005U-07 Room 345 13:09 15:10 10 10 1210 <0.055 < 0.01 Air Quality A011005U-08 09 Room 322 Swan Claims__________ 13:14 15:12 JO. 10 1180 0.070 < 0.01 Air Quality A011005U-09 JO Room 225______________________ 13:20 15:14 10 10 1140 0.060 <0.01 Air Quality A011005U-10 11 Field Blank_____________________ <0.055 A011005U-11 12 Field Blank <0.055 A011005U-12

TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY); TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING, 6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY): O SAMPLING TECHNICIAN: Z.B Nowak / M, Tchatchueng DATE RECEIVED: 10/05/01 ROTAMETER: KAM- 04 DATE OF ANALYSIS: 10/06/01 DATE OF REPORT: 10/08/01 Analyst: Lab Man: ier:_J o Alex Barengolts David Chen O The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area. O KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program. I The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory. o The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. co NYS-DOH ELAP # 11273 AIHA # 100269 co 1 cn o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251714Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000178214

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178188

Laboratory report from KAM Consultants detailing phase contrast microscopy results of air filters collected for DCAS.

Similar indexed content

Compare copies and versions →