Long Island City REPORT OF AIR MONITORING
1^ New York, 11106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) “0
c
o
o
Tel: 718)729-1997 CT
o
ro Fax: 718)729-1876 CLIENT: DCAS DATE: 09/24/01 o'
Oi PROJECT: ADDRESS: 49-51 Chamber Street, Manhattan "0
o
o>
CD CD
cn R W
CLIENT FLOW FLOW SAMPLE FIBERS FIBERS 0
E O TIME TIME O
SAMPLE LOCATION BEF. AFTER VOLUME PER PER REMARKS LAB ID#
S R IN OUT O
ID# (Ipm) (Ipm) (liters) FIELD CC c
P K 3
o
24 3rd Floor - West Elevators 19:23 21:23 10 10 2^ <0.055 <0.01 Air Quality (Immed. TAT) A0109251-24 3
25 1st Floor - West by Elevators_______ 19:25 21:25 10 JO. 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010925I-25
26 1st Floor - East by Elevators_______ 19.36 21:36 10 JO. 1200 <0,055 <0.01 Air Quality (Immed. TAT) A0109251-26
27 Lobby - 49 Chambers Main Entrance 19:37 21:37 10 JO. 2200 0.060 <0.01 Air Quality (Immed. TAT) AOI 09251-27
28 Lobby - 49 Chambers By Elevators 19:40 21:40 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010925I-28
29 Basement - By Elevators__________ 19:42 21:42 10 JO. 1200 <0,055 <0.01 Air Quality (Immed. TAT) A010925I-29
30 Basement - In Locker / Bathroom 19:43 21:43 10 10 1200 <0,055 <0.01 Air Quality (Immed. TAT) A010925I-30
31 Field Blank <0.055 A010925I-31
32 Field Blank 12,055 AOI 09251-32
33 Field Blank <0.055 A0109251-33
TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY):
TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING,
6 = ENCAPSULATION, 7 - BAGOUT, 8 = OTHER (SPECIFY):
o SAMPLING TECHNICIAN: M. Tchatchueng / Z.B Nowak DATE RECEIVED: 09'25/01
ROTAMETER: KAM- 02 DATE OF ANALYSIS: 09/25/01
DATE OF REPORT: 09/26/01
Analyst: Lab Manager:
leepak Bajracharya David Chen
o
The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area.
o KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program.
o
I The results relate only to the items calibrated or tested. The cerlificate of report shall not be reproduced without approval of the laboratory.
o
The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S, Government
co NYS-DOH ELAP #11273 AIHA # 100269