Z KAM CONSULTANTS z
o 35-40 36lhStreet o
l^nsL Long Island City co
g REPORT OF AIR MONITORING
o New York, 11106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS)
I “0
O
O
Tel: 718)729-1997 c
CT
O Fax: 718)729-1876 CLIENT: DCAS DATE: 10/02/01
o'
PROJECT: ADDRESS: 111 Centre Street, Manhattan "0
00 o
KJ 12th, 10th, 8th, Sth, 3rd, Main Lobby & Basement
CT) R W CD
CLIENT FLOW FLOW SAMPLE FIBERS FIBERS
E O TIME TIME 0
SAMPLE LOCATION BEF AFTER VOLUME PER PER REMARKS LAB ID# o
S R IN OUT o
ID# (Ipm) (Ipm) (liters) FIELD CC c
P K
3
24 3rd Floor - Room 340 14:38 16:38 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) AO1100213-24 o
3
25 Main Lobby - By Main White Street Entrance Lobby 15:55 18:05 10 10 1300 0.070 < 0.01 Air Quality (Immed. TAT) AO1100213-25
26 Main Lobby - Room 106 15:56 18:06 10 10 1300 <0.055 <0.01 Air Quality (Immed. TAT) A01100213-26
27 Main Lobby - Room 107_________________________ 15:58 18:08 10 10 1300 <0.055 <0.01 Air Quality (Immed. TAT) A01100213-27
28 Baso.nent - By Exit B_____________________ 16:18 18:18 10 10 1200 <0.055*’ <0.01 Air Quality (Immed. TAT) A01100213-28
29 Basement - Corridor to Garage__________ 16:19 18:19 10 10 1200 <0.055! <0.01 Air Quality (Immed. TAT) A01100213-29
30 Basement - Garage By Spot # 36 16:16 18:16 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) AO1100213-30
31 Field Blank <0.055 A01100213-31
32 Field Blank <0.055 A011002I3-32
33 Field Blank <0.055 AO1100213-33
TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY):
TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING,
6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY):
o
SAMPLING TECHNICIAN: Z.B Nowak / M. Tchatchueng DATE RECEIVED: 10/02/01
K ROTAMETER: KAM- 04 DATE OF ANALYS IS: 10/03/01
I
ro DATE OF REPORT: 10/03/01
Analyst; Lab Manager:
Deepak Bajracharya David Chen
o The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area.
o
I KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program.
o
The results relate only tc the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory.
co The report must not b; used by the client to claim endorsement by NVLAP or any agency of the U.S. Government.
co NY.S-bOH ELAP# 11273 AfllA # 100269
cn 2
OCR can misread numbers and units. Confirm readings against the page image before using them.