z z KAM CONSULTANTS 35-40 36th Street o

I^am co § Long Island City REPORT OF AIR MONITORING s o o ro New York, 11106 Tel: 718 729-1997 Fax: 718 729-1876 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) CLIENT: DCAS DATE: 09/19/01 “0 c CT o' tn PROJECT: CITY HEALTH BUILDING ADDRESS: 22 Reade Street, Manhattan, NY "0 cn o CD CD KJ R w 0 CLIENT FLOW FLOW SAMPLE FIBERS FIBERS O E O TIME TIME SAMPLE LOCATION BEF. AFTER VOLUME PER PER REMARKS LAB ID# O S R IN OUT c ID# P K (Ipm) (Ipm) (liters) FIELD CC 3 o 3 01 6th Floor Loby By Elevators 14:31 15:31 15 15 9Q0 <0.055 < 0.01 Air Quality (Immed. TAT) A010920B-01 02 6th Floor South East Area 14:32 15:22 Ts 15 90^ <0.055 <0.01 Air Quality (immed. TAT) A010920B-02 "os 6th Floor South West Area 14:33 15:33 7^ Ts <0.055 <0.01 Air Quality (Immed. TAT) A01092OB-03 "m 5th Floor Lobby By Elevators 14:43 15:43 15 15 900 "<0:05^ <0.01 Air Quality (Immed. TAT) A010920B-04 05 5th Floor South East Area 14:44 15:44 7? 15 900 <0.055 < 0.01 Air Quality (Immed. TAT) A010920B-05 06 5th Floor South West Area 14:45 15:45 15 15 W '<0'05^ <0.01 Air Quality (Immed. TAT) AO10920B-O6 07 4th Floor Lobby By Elevators 14:55 Ts^ 15 15 900 0080 < 0.01 Air Quality (Immed. TAT) A01092OB-07 08 4th Floor South East Area 14:56 15:56 15 15 900 0.105 < 0.01 Air Quality (Immed. TAT) A01092OB-08 '09' 4th floor South West Ara 14:57 15:57 15 Ts goo" 0.070 < 0.01 Air Quality (Immed, TAT) A010920B-09 To" 3rd Floor Lobby By Elevators 16:15 21:15 15 7^ <0.055 < 0,01 Air Quality (Immed. TAT) A010920B-10 7T 3rd Floor South East Area 16:16 17:16 15 Ts 900 0.060 < 0,01 Air Quality (Immed. TAT) A010920B-11 TF 3rd Floor South West Area 16:17 17:17 7? TF 900 <0.055 <0,01 Air Quality (Immed. TAT) A010920B-12 Ta" 2nd Floor Lobby By Elevators Ters' 17:28 15 Ts <0.055 <0,01 Air Quality (Immed. TAT) A010920B-13 TT" 2nd Floor South East Area 16:29 17:29 15 Ts 900 0.065 <0,01 Air Quality (Immed. TAT) A010920B-14 ■7? 2nd Floor South West Area 16:30 17:30 TK 75 900 <0.055 < 0,01 Air Quality (Immed. TAT) A010920B-15 7? 1st Floor Lobby By East Elevator 16:41 17:41 75 15 <0.055 < 0,01 Air Quality (Immed. TAT) A010920B-16 17 1st Floor Lobby By Main Entrance 16:42 17:42 15 15 900 "<0:0^ < 0,01 Air Quality (Immed. TAT) A010920B-17 18 1 st Floor By West Elevator 16:43 17:43 15 Ts 900 <0.055 < 0,01 Air Quality (Immed. TAT) A010920B-18 77 1st Floor By West South Area 16:44 17:44 7^ 75 <0:055 <0,01 Air Quality (Immed. TAT) A010920B-19 To" Field Blank <0^55 A010920B-20 21 Field Blank <0.055 A010920B-21

TYPE OF RESPIFiATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C. 4 = OTHER (SPECIFY): TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING, 6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY): O SAMPLING TECHNICIAN: Z.B. Nowak DATE RECEIVED: 09/20/01 A ROTAMETER: KAM- 04 . DATE OF ANALYSIS: 09/20/01 I 1"^ DATE OF REPORT: 09/20/01 Analyst; Lab Manager: g Deepak Bajracharya David Chen O The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter ar o KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program. o I The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory. o The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. co NYS-DOH ELAP # 11273 AIHA # 100269 co 1 Ui Ui

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251662Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Air monitoring report, WTC site, Sep 2001

NYC-WTC_000178273

Report from KAM Consultants detailing phase contrast microscopy analysis of air filters for DCAS at the World Trade Center site.

Similar indexed content

NYC-WTC_000178204

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178241

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178188

Laboratory report from KAM Consultants detailing phase contrast microscopy results of air filters collected for DCAS.

Similar indexed content

Compare copies and versions →