EPA WTC interim report comments, 2003

Machine-extracted title · confidence 28%

Comments on EPA interim report regarding World Trade Center collapse from 2003.

NYC-WTC_000251148–000251575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

D: EPA, NYC, and FEMA admissions of hazards - 55

Report by EPA’s ORD admits hazardous exposures

A draft report issued 10/02 by EPA’s Office of Research and Development contained findings which constitute admissions of at least potential, as yet undefined hazards. All of the data summarized in the EPA ORD report had been available to EPA and the public as soon as September, 2001, and the immediate months that followed. Thus, EPA cannot claim that any information in the 10/02 draft ORD report was new to them.

Except for exposures on September 11 and possibly during the next few days, persons in the surrounding community were unlikely to suffer short-term or long-term adverse health effects caused by exposure to elevations in ambient air concentrations of the contaminants evaluated in this report. These elevated concentrations were measured mostly within and very near Ground Zero, and they lasted for 1 to 3 months after September 11.... Exposures that were specific to the indoor environment were also not explicitly addressed in this assessment..,. This assessment focuses on the inhalation pathway. Exposure can potentially occur via inhalation, dust ingestion and dermal contact with contaminated dust on surfaces. ... The health assessment conducted in this study assumed that ambient air measurements were representative of long- and short-term exposures. In some cases, this could be misleading or inappropriate, particularly if indoor concentrations are higher than outdoor concentrations. It is emphasized that the evaluations in this document focus on ambient, outdoor measurements. [Emphasis added. Note that the report carefully differentiates between ambient and indoor exposures.]

Some additional future considerations could include: evaluating other contaminants that were measured, evaluating the indoor environment in more depth, evaluating other pathways of exposure and other exposure media such as dermal contact to contaminated dust, investigating the combined effects of exposure to more than one contaminant, conducting further toxicity testing with laboratory animals, and considering results from ongoing epidemiological studies.

After late September, indoor exposures to such dust probably warrant more concern than outdoor exposures for possible acute irritative effects or more chronic health effects, not only because of the basic nature of some constituent particles but also because of other unusual features, such as slender microscopic glass fibers with toxic materials attached to them or very fine particles composed of unusual combinations of silica coalesced with lead or other toxic materials.

However, susceptible persons (especially any pregnant women) who may have experienced extended exposures to elevated Pb levels within WTC Ground Zero work areas while not wearing appropriate respiratory protective gear or who were exposed to indoor WTC-derived dusts with high Pb loadings could possibly be at increased risk for chronic health effects.

Limited available evidence suggest the incursion of asbestos to the indoor environment. A small study which sampled the indoor environment of two apartments on September 18 showed very high indoor levels of asbestos. A larger and more systematic study which sampled in November and December of 2001 suggested that indoor levels of asbestos in dust were slightly higher near the WTC as compared to indoor levels in dust

NYC-WTC_000251212

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251212Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →