P: Carpet and porous material testing and cleaning - 267

■ EPA 110 Liberty St. study proves HEPA vacuuming and shampooing doesn’t work

On 6/4/03, EPA released the results ofits WTC dust pilot cleaning study at 110 Liberty St. in NYC. This report is discussed in detail in Section G.

The only method EPA used to test porous surfaces like carpeting before and after cleaning was with the ASTM microvacuum sampling method. It would have been much better to have used EPA’s ultrasonification extraction method, the accepted EPA method for carpets and porous materials.

Nevertheless, the 110 Liberty St. study showed that there were no significant reductions of asbestos in carpet and other soft materials before and after EPA’s elaborate abatement procedures.

In feet, of the 11 apartments where porous surfaces (carpet, etc.) were tested with the ASTM microvacuum method, 4 had some higher levels of asbestos after cleaning than before. That is correct, the concentrations were higher after cleaning. For 3 apartments, the levels were about the same, and for 4 apartments, the levels were lower.

Pre-cleaning sampling also included the collection of micro vacuum samples from up to six porous surface areas (e.g., carpets, furniture fabric) in twelve of the thirteen residential units, and both commercial units included in the study (Mattress Store, Chiropractor’s Office). The samples were collected from a 10 cm x 10 cm area using dedicated, disposable templates which were left in place. Each unit contained a different number of porous surface sample areas, except Unit 4B which did not have any porous surfaces from which to collect a sample. The micro vacuum samples were analyzed for lead and for asbestos (TEM).

[Interim Final V\n'C Residential Confirmation Cleaning Study, 110 Liberty St, NY New York, NY, 5/03, EPA Region 2, http://epa.gov/wtc/interim_wtc_residental_study2.pdf ]

This EPA study shows that the cleaning methods were ineffective in removing asbestos from porous soft materials and objects. EPA used dry HEPA vacuuming on couches and personal belongings. For carpeting, EPA used dry HEPA vacuuming followed by wet extraction (shampooing).

EPA did not provide any of the actual results of the microvacuum sampling of the soft materials in its report. There was not enough time to obtain them for inclusion in this report.

NYC-WTC_000251423

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251423Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →