K: 1% asbestos in settled dust - 215

When the study simulated residential activities in the attic, such as moving around boxes, air asbestos levels were as high as 0.43 s/cc by TEM, which is 20 times the AHERA clearance level.”

Removal of the vermiculite insulation by the homeowner resulted in concentrations as high as 0.60 s/cc TEM, or 27 times the AHERA TEM clearance level.

These levels inside a house are much higher than what EPA measured in outside air at Ground Zero. As noted elsewhere, air concentrations in a confined space, such as a house or apartment, will be much higher than outside, even if the dust contains the same percentage of asbestos.

We would expect even higher levels in air for thick layers of WTC dusts, since they are more finely divided than vermiculite attic insulation, and more easily resuspended. There are no studies to my knowledge which tested air levels of asbestos for substantial accumulations of WTC dusts in a confined space where there were either actual or simulated human activities. All air tests by EPA were conducted only after extensive abatement, or prior to abatement under passive conditions. The studies by the Ground Zero Task Force and HP Environmental were also under passive conditions, meaning that the dusts on surfaces were undisturbed.

The elevated levels found in the EPA vermiculite attic insulation study could represent the minimum level to which NYC citizens were exposed when they removed the original layers WTC dust from their homes or offices using the NYC DOH do-it-yourself cleanup guidelines.

Using a HEPA vacuum would not have been any protection whatsoever from the elevated airborne levels generated by heavy dust layers, since simple movement in the dust by the person or cleaning equipment would resuspended fibers. The HEPA vacuum would never have a chance to remove them, a.s demonstrated by EPA studies on air levels during HEPA vacuuming.’’

Early criticisms that 1% asbestos is not an EPA safe level

The following is documentation that 1% asbestos is not a safety standard fi-om my 12/3/01 and 3/11/02 memoranda. This alleged 1% safety level was also addressed in my 12/19/01, 1/11/02, and 2/10/02 memoranda.

3/21/02 In the days after Sept. 11, EPA officials used standards to determine dangerous asbestos contamination that were never intended to measure health risks, according to a new 43-page memo by a dissident Environmental Protection Agency scientist.

Cate Jenkins, a 22-year veteran with the agency's Hazardous Waste Identification Division in Washington, charged that the agency "misrepresented safety levels and standards for asbestos" and failed to accurately detect possible health risks to the public.

NYC-WTC_000251371

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251371Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →