J: Air testing and standards - J97

airborne asbestos at levels that are shown to cause excessive cancers... . EPA is conducting the AHERA TEM clearance test under oassjivA conditinny when the dusts are not being disturbed.... any activities which stir up dusts will result in vastly higher airborne asbestos concentrations.

By even performing the AHERA TEM clearance test in lieu of professional asbestos abatement, EPA is violating the AHERA regulations. This is because the AHERA TEM clearance test is only allowed in conjunction with a whole range of asbestos abatement procedures that go on prior to even taking the test. It was designed to catch only gross contamination problems caused by some worker on the asbestos abatement project, such as emptying one bag of asbestos contaminated material into another inside a room that had previously been carefully abated... . [Jenkins, 1/11/02]

2/10/02 The reason that the EPA designed the AHERA TEM clearance test, requiring first certified asbestos abatement procedures followed by a leaf blower, and then a fan, followed by air testing to the 0.01 f/mL (PCM) level (equivalent to 0.02 s/mL or 70 structures per square millimeter) was to save costs and time. EPA found that using a leaf blower increased asbestos concentrations in air by thousands of times. One study showed that using a leaf blower increased airborne asbestos concentrations over 100 times that caused by even vigorous broom cleaning. And vigorous broom cleaning has been demonstrated to increase asbestos levels hundreds or thousands of times over that of passive conditions which do not disturb dusts. Testing at the low levels that are actually those of health concern, 0.000004 f/mL, can often take 24 or more hours, which was found to be impractical for asbestos abatement contractors.

Even if testing is done at the low levels associated with asbestos health effects (0.000004 f/mL), there must be human activities or simulated human activities in the same room at the same time of the testing. When testing airborne asbestos levels inside homes in Libby, Montana, the Superfund site, EPA had both stationary air monitors and monitors worn by residents going about their normal daily activities. See the attached risk assessment for the Libby site for a description. Another study showed that asbestos concentrations in air can be undetectable or below 0.005 f/mL when there are no activities in the room to stir up dusts, but as high as 0.09 to 54 f/mL when activities such as vacuuming, broom sweeping, gym activities, etc. are going on in the room to disturb the dusts.

The EPA standard for asbestos in indoor and outdoor air is found in its Integrated Risk Management Information System (IRIS), attached, and other public documents. It is the policy and goal of EPA to protect at the 1 in a million cancer risk level (10'® risk level), the point of departure. In all cases, action by EPA is triggered by any risk greater than 1 in 10,000. The EPA air standards for asbestos in inside and outside air at the different risk levels are given in the table below;

CANCER RISK LEVEL AIR CONCENTRATION OF ASBESTOS fibers per milliliter (f/mL), ‘PLM' fraction of number of cancers risk level fibers over 5 micrometers long

' in 1,000.000 10‘ 0.000004 f/mL (=E-6) (= 4E-6 f/mL)

NYC-WTC_000251353

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251353Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →