G: EPA’s 110 Liberty St. study, Deutsche Bank building - 137

Asbestos not an indicator of lead - 110 Liberty St. study demonstrates fact

Before abatement, only 23% of apartments had safe levels of lead (only 3 out of 13 apartments had safe levels). Most of the apartments (7 out of 13) did not even have visible WTC dust, except around the heating baseboards.

Asbestos testing was not a good enough indicator of whether hazardous lead levels had been abated. 18% of the apartments which still had hazardous levels of lead after one EPA abatement passed the asbestos test, but not the lead test. In other words, if EPA had relied only on asbestos testing to determine whether lead was still present at hazardous levels, then a significant number (18%) of apartments that had high lead would have gone unnoticed. The EPA 110 Liberty St. study concluded the following, which is totally false and unsupported by the data;

The study found that conducting asbestos in air sampling after cleaning could be used as a surrogate method for determining if future cleaning was needed.

[Interim Final WTC Residential Confirmation Cleaning Study, 110 Liberty St, NY New York, NY, 5/03, EPA Region 2, p. 114, http://epa.gov/wtc/confirmation_clean_study.htm 1

Undoubtedly, EPA put this knowing feLse claim into the conclusion section of its 110 Liberty St. study because the EPA voluntary cleanup program, already in progress, was only testing for asbestos. The 110 Liberty St. results came after the EPA cleanup program was set up with its intentions to only test for asbestos had been announced to the public. EPA had a vested interest in justifying the asbestos-only testing in EPA’s cleanup program.

Failure to Warn

EPA had the results of the 110 Liberty St. study by the third week in October, 2002. (See page 17 of EPA study.) They had all of the air tests and dust test results, because they needed this information to determine whether the abatement was complete. They knew that even apartments containing minimal dust was resulting in hazardous conditions after one abatement, and they knew that the dust itself contained less than 1% asbestos.

They knew that their extraordinary abatement measures, including taking appliances out from the wall, elevating them and using specialized brushes while simultaneously HEPA vacuuming, abating the roof, facade, common areas twice, abating the HVAC systems and all units at the same time, sealing off units after abatement to prevent recontamination, removal of furniture and personal belongings prior to abatement and testing, etc., was not always successful in bringing asbestos, lead, and fiberglass levels down to even EPA’s lenient benchmark levels. They knew

NYC-WTC_000251293

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251293Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →