EPA WTC interim report comments, 2003

Machine-extracted title · confidence 28%

Comments on EPA interim report regarding World Trade Center collapse from 2003.

NYC-WTC_000251148–000251575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

G: EPA’s 110 Liberty St. study, Deutsche Bank building - 134

Unit 2A This unit i s located on the second floor. It is a 1,335 sq. ft. loft with one bedroom facing Cedar Street. The unit has hardwood floors. The unit presented minimal dust accumulation in the dwelling with the exception of the baseboard-heating units. The windows were not blown in. All personal items were disposed except for a couch and chairs.

Post 2nd Cleaning Samples .. . The TEM AHERA results were all below the secondary numeric criterion of 0.022 S/cc; [the equivalent of 70 s/mrrf, the AHERA level] two of the six samples were below the detection limit. The PCMe results were at or below the primary clearance criterion of 0.0009 S/cc ...

Unit 4C This unit i s located on the fourth floor. It is a 655 sq. ft. open loft that faces the WTC site. The windows were blown in and there was significant dust accumulation in the dwelling. The unit has hardwood floors and no carpet. All personal possessions to be retained by the tenant were vacuumed and bagged.

Post 1st Cleaning Samples ... The TEM AHERA results were above the detection limit but were below the secondary numeric criterion of(1022 S/cc. Two of the three air samples analyzed using PCMe were below the primary clearance criterion of 0.0009 S/cc. The third air sample detected chrysotile and was present at the primary clearance criterion of 0.0009 S/cc.

Unit 4D This unit i s on the fourth floor. It is a 968 sq. ft. open loft facing the WTC site. The unit had windows blown in and presented a significant accumulation of dust. The dwelling has hardwood floors with no carpet. All personal possessions to be retained by the tenant were vacuumed and bagged.

f’ost 1st Cleaning Samples ... The TEM AHERA results indicate that all three samples were below the secondary numeric criterion of 0.022 S/cc. The PCMe results indicate that two of the three air samples were below the primary clearance criterion of 0.0009 S/cc. The third sample detected chrysotile and was at the primary clearance criterion of 0.0009 S/cc.

Unit 5C This unit is located on the fifth floor. It is a 968 sq. ft. loft with three separate bedrooms facing the WTC. The unit has hardwood floors. Windows were blown in. There was significant accumulation of dust in the dwelling. All of the tenant's personal items were removed prior to cleaning. ... The results for two of the three micro vacuum samples indicate that asbestos was present at levels similar to those observed before cleaning. The third micro vacuum sample was reported as being below the detection limit.

F’ost 3rd Cleaning ... The TEM AHERA results had chrysotile detected above the detection limit; however, all four results were below the secondary numeric criterion of O.,Q22S/cc. ... The remaining two samples, collected under an aggressive sampling methodology, were (1 % times EPA’sl clearance criterion of 0.0009 S/cc with results of 0.0015 S/cc and 0.0016 S/cc. The results obtained from the samples collected with the modified-aggressive sampling were used as evidence of meeting the primary clearance criterion.

Chiropractor’s Office This is a 716 sq. ft. office space with four examination rooms facing the World Trade Center site. All front windows were blown in. Significant amounts of dust were present on all horizontal and vertical surfaces. Floor areas were covered

NYC-WTC_000251290

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251290Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →