G: EPA’s 1 JO Liberty St. study, Deutsche BanJc building - 127

Apt, 5C, abatement of an apartment with “significant” WTC dust

Apartment 5C is located on the fifth floor. It is a 968 sq. ft. loft with three separate bedrooms facing the WTC. The apartment has hardwood floors. Windows were blown in. There was significant accumulation of dust in the dwelling. All of the tenant’s personal items were removed prior to abatement. The windows were sealed and the bathroom fan vent was also sealed. There was no HVAC system supplying this apartment. Thus, this apartment presented a best-case scenario for any air testing afterwards, since the major reservoirs for asbestos and other airborne contaminants were removed: i.e., no carpet, sealed windows, no personal possessions, and any vents sealed off

Abatement Methods: In addition to the procedures used throughout the building described earlier in this section, this apartment was abated the first 2 times using an industrial HEPA-filtered vacuum for vacuuming the floors and other surfaces. All horizontal surfaces were wet wiped with soapy water. The apartment failed testing even after 2 abatements.

For the 3’^'* abatement, An air filtration device (AFD) was added. An AFD is a local exhaust system with HEPA filtration that is capable of creating and maintaining a negative pressure differential between the outside and the inside of the work area. The AFD functions as a stand­ alone piece of equipment in a room. The AFD was used as an air-polishing device, to capture dust particles tliat became airborne as a result of disturbances caused by the abatement activities.

Asbestos: After the 1“ abatement, 3 air samples were analyzed using both PCM and PCMe. One air sample exceeded the NYC DOH criterion level of 0.01 f/cc, the approximate equivalent of the AHERA clearance level of 70 s/mmf This air sample showed asbestos levels of 0.015 Fee. In other words, even after a rigorous professional abatement by EPA as described above, an air test showed asbestos levels exceeding the lenient NYC DOH standards, and far exceeding EPA’s criteria of 0.009 S/cc PCMe.

After the P' abatement, air was also tested to see if it met EPA’s criteria for asbestos in air that might protect against an excess cancer risk of 1 in 10,000. This is the ten-to-the-minus four, or 10 '* risk level. This level is 0.0009 S/cc “PCMe” PCM-equivalents. The laboratory was unable to provide any results, because the filter was overloaded and asbestos fibers could not be seen.

After the 2"*’ abatement, EPA tried to perform 3 different types of air tests by the PCM, TEM AHERA, and PCMe methods. None of the asbestos air tests could be read by the analysis, because all of the filters were overloaded. .

After the 3'*’ abatement, the PCMe results indicated that two samples, collected under EPA’s aggressive sampling methodology, were above the primary clearance criterion of 0.0009 S/cc with results of 0.0015 S/cc and 0.0016 S/cc.

NYC-WTC_000251283

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251283Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →