NYC 9/11 Public Portal Document

70 s/mrn^ - AHERA must be used in combination with a leaf blower (aggressive testing) in an enclosed space to be relevant to predicting risks

The law (through implementing regulations) requires this combination

You can't have one without the others

The 70 s/square millimeter level must always be coupled with the use of a one- horsepower or greater leaf blower in an enclosed space, following a certified professional abatement, and other requirements. YOU CAN’T HA VE ONE WITHOUT THE OTHER REQUIREMENTS.

Tlie regulations are explicit about aggressive testing:

40 CFR Part 763 Subpart E - Asbestos-Containing Materials in Schools

(1) At the conclusion of any action to remove, encapsulate, or enclose ACBM [asbestos containing building materials]... A person designated by the local education agency shall collect air samples using aggressive sampling as described in appendix A ...

Appendix A ... The following appendix contains three units. The first unit is the mandatory transmission electron microscopy (TEM) method which all laboratories must follow ...

d. After the area has passed a thorough visual inspection, use aggressive sampling conditions to dislodge any remaining dust.

iii. Prior to air monitoring, floors, ceiling and walls shall be swept with the exhaust of a minimum one (11 horsepower leaf blower.

iv. Stationary fans are placed in locations which will not interfere with air monitoring equipment. Fan air is directed toward the ceiling. One fan shall be used for each 10,000 ft 3 of worksite. [emphasis added]

[The Code of Federal Regulations are available from most larger libraries, all law libraries, and also online at: http://www.access.gpo.gov;nara/cfr/index.html, or for EPA-regulations only (faster) at http:/A<vww.epa.aov/epahomeZcfr40.htrn ]

Reasons why EPA and laboratories misuse the term "AHERA test"

EPA, laboratories, and contractors usually misuse the term “AHEIIA test.” There are several reasons for this.

First, the laboratory who receives the sample does not have any ide a whether or not

- 20 -

CITY_21MC1OO_O13381569

NYC-WTC_000250749

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250749Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →