NYC 9/11 Public Portal Document
The AHERA regulations were promulgated to protect school children from exposure to asbestos.
This regulation defines inspection and management requirements as well as clearance re
occupancy testing requirements. The re-occupancy testing requirements are designed to
facilitate re-occupancy of a classroom following an asbestos abatement action. The AHERA
regulations apply to all public school buildings from K though 12* grade. In accordance with
AHERA, an abatement action can be considered complete and the classroom reoccupied by
school children when the results of final clearance air samples collected within the work area are
less than 70 sli7mm\ In fact the AHERA regulations allow for a statistical analysis of the
clearance data relative to 70 str/mnY, which allows some samples to be greater than 70 strmm7
The clearance criteria for this project required that all results be less than 70 str/mm^, which in
fact is stricter than the AHERA regulations for school children.
Sampling Methodology
The air samples are collected by drawing air through a mixed cellulose ester filter (MCE), 25
millimeters (mm) in diameter, with a pore size of 0.45 micrometers. The air is pulled by a 120-
volt AC powered, constant flow vacuum pump operated at nominal flow rate of 10 liters per
minute (1pm). The pumps are calibrated prior to sampling, using a secondary calibration
standard (rotometer). The secondary calibration standards are calibrated periodically (at least
once every six months) using a primary standard. The flow rate of each pump is rechecked
following each sampling period.
To analyze a sample, circular sections of the filter are cut and placed on a clean glass slide. The
slide(s) is then placed in a petri dish containing acetone to fuse and clear the filters. The filter is
then plasma etched and transferred to a rotating stage inside a bell jar of a vacuum evaporator. A
1- by 5-mm graphite rod is than evaporated on the filter and the filter is transferred to a clean
petri dish. A wicking substrate covered with filter or lens paper is then placed in another petri
dish. Carbon-coated TEM grids are then placed on the filter or lens paper and acetone is placed
in the petri dish until the wicking substrate is saturated. A portion of the carbon-coated filter is
removed from the glass slide and placed carbon-coated side down on a labeled grid in the
acetone saturated petri dish.
21
CITY_21 MC100_014587103
NYC-WTC_000243726
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000243726Source: NYC Law Department, mirrored locally