NYC 9/11 Public Portal Document NYC-Dept.of Health Fax••212-349-5170 Oct 25 ’01 9:22 P.02/03

Preliminary Review Indoor Sampling for Public Health Evaluation in Buildings Near the World Trade Center Disaster, IRB Protocol Number 01-062.

Essence: ■.

X. ■ < The collapse of the World Trade Center (WTC) resulted in the evacuation of a large number of o ■ residents and office workers from their homes and places of business. Although residents are ; gradually being allowed to re-occupy their homes near ground zero, environmental sampling efforts 1 must now ensure that these dwelling units receive public health evaluation to identify and remove , respirable dust deposited on surfaces exposed (through open or broken windows) to debris deposited ' following the collapse of the WTC. <s- The research is a pilot investigation of dust contamination and air quality within residential buildings located at varying distances from the WTC site. Sampling of visible dust and ambient indoor air will be performed for asbestos, crystalline silica, total suspended particulate matter, and fractionation of silica dust into a size distribution for inhaled, thoracic, and respirable silicates. The sampling frame will include 50-60 dwelling units stratified according to the 4-tiered buffer zone established for the debris field. Both occupied and un-occupied dwellings will be included in the survey. When occupants are present during sampling procedures, the building. HVAC system will be set at continuous operation to ensure an appropriate air exchange rate.

Dust concentrations within the three tiers in closest proximity to the disaster site will be compared against the baseline zone created within tier 4 (at greatest relative distance from WTC). At the end of study, analytical results (dust concentration levels for the measurable parameters) will be provided (with an explanation of significance) for each property owner where sampling was performed. Consent will be obtained for access to property and for authorization to share test results with local, state, and federal, health and environmental agencies.

Preliminary Protocol Review Issues

1- The protocol should explain what personal protective equipment/actions! will be used/taken to : prevent exposure ofDOH employees (contractors) performing sample collection and, residents who will have been allowed to occupy their dwellings prior to the time of sampling. Will residents and their families be asked to leave the rooms while sampling is ongoing? The protocol’s consent form should describe plans (if any) for isolation of areas where sampling will occur, and provide a statement that operation of the air sampling equipment will (or will not) disrupt free movement ■ through the (occupied) apartment.

2- A copy of the Quality Assurance/Quality Control (QA/QC) Plan developed by the laboratory contractor (RMLS) should be provided for review (when available) along with a revised protocol for the final sampling/analytical methods. In addition, the Environmental Laboratory Approval Program (ELAP) number or comparable certification number should also be provided for EMLS confirming that the contractor demonstrates required proficiency to conduct tests for dust (fiber) concentrations.

■

‘■ciTY_21MC106_013489497 NYC-WTC_000250617

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250617Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →