NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗DOH page showing page 1 of sampling protocol for WTC residential areas.
NYC-WTC_000250606–000250616OCR status: ok · source: pdftotext
z z ■<
o co
'2 o o Sample/Analytical Methods [NOTE: screening levels dictate detection/quantitation limit needs] “0 c CT KJ o' cn "0 o Parameter Environmental.Media Sampling/Analytical Method Sample Flow/time Analytical LOP / LOO* o C3> 03 o ; O Asbestos I/O** air NIOSH 7400, NIOSH 7402 16 L/min -4 hr (3840L) 0.010 f/cc (LOQ) o o Breathing zone sample height 5 hr (4800L) 0.008 f/cc c 3 6 hr (5760L) 0.007 f/cc CD 3
Inhalable (< 100 pm) I/O air lOM personal sampler. Analyze each 2 L/min -5 hr (600L) 30 ug / 50 ug/m’ thoracic (<10pm) fraction for asbestos,(TEM), and for respirable (<4pm) crystalline silica, gypsum, fiberglass calcite (XRD)
Respirable I/O air NIOSH 7500 2.5 L/min-5.3 hr(800L) 5 ug / 6 ug/m^ crystalline silica
pH I/O dust EPA SW 846 Mtd 9045C (soils) 10-25 g
asbestos I/O dust PLM, and if <1% TEM tt
n asbestos, gypsum, I/O dust XRD mica, fiberglass calcite
* LOD:Limit of analytical detection; LOQ: Limit of analytical quantitation ** I: indoor; O: outdoor
Vn. Screening Levels/Data Interpretation: Screening levels will be developed for respirable crystalline silica and PM in air; and for asbestos in vacuum dust and outdoor surface n dust samples.
Data will be evaluated by local, state and federal public health agencies. Evaluations will include: n o Page 8 of 11 o I
Ji*
co
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250536
ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241970
Draft protocol addressing settled surface dust and airborne materials post-WTC collapse.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320050
Draft ATSDR/DHAC evaluation of ambient and indoor dust near WTC with asbestos data.
12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317962
Lab evaluation of residential dust near WTC for asbestos and related contaminants (draft).
12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153247
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152825
Draft protocol establishing procedures for evaluating airborne and settled dust in residential and commercial areas near the World Trade Center.
13 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153241
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000153247
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152825
Draft protocol establishing procedures for evaluating airborne and settled dust in residential and commercial areas near the World Trade Center.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307837
Draft protocol for ambient and surface dust sampling near WTC after collapse.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153258
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similar indexed content
NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
Similar indexed content
NYC-WTC_000152825
Draft protocol establishing procedures for evaluating airborne and settled dust in residential and commercial areas near the World Trade Center.
Similar indexed content
NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
Similar indexed content
NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
Similar indexed content