NYC-WTC_000241970
Draft protocol addressing settled surface dust and airborne materials post-WTC collapse.
15 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
NYC-WTC_000250536–000250546OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
IV. Sampling Parameters: Parameter Sample Type Indoor/Outdoor Rationale for Selection Asbestos breathing ht., I/O known use in building construction, evidence of time-weighted presence in early air sampling and in settled dust, air known inhalation carcinogen
Total Suspended breathing ht., O Characterize amount of airborne dust that is particulates Continuous, real inhalable (slOO pm aerodynamic diameter) time, air
PM10andPM2.5 breathing ht., O Characterize the amount of airborne dust that is Continuous, real respirable time, air
Inhalable (<100pm)' breathing ht., I/O To determine relative amounts of each fraction present thoracic (<10pm)’ time-weighted, and to have each fraction analyzed for silica, gypsum, respirable (<4pm)' air asbestos, mica, and calcite to qualitatively determine potential hazards.
Respirable breathing ht., I/O Known component of concrete, evidence of crystalline silica time-weighted, presence in some settled dust samples, known air inhalation carcinogen.
pH" dust I/O Concrete has a high pH, if dust has a high pH, it may be contributing to reported symptoms of ENT irritation
Asbestos” dust I/O Determine if asbestos is present in dust
gypsum, mica, dust I/O Associated with building materials (concrete, calcite” diynvall) and known to be irritating to ENT
magnesium dust I/O May act as a (racer for WTC-rclalcd dust, levels found in metals analysis of settled dust from 16,000-29,000 ppm ■ results will be used to better understand the potential for ENT and respiratory irritation, and possibly for detennining the possibility of acute/chronic health problems. Results will assist in providing information/recommendations to the public (e.g., what is contributing to irritation, how to reduce exposures) n ’* to assist in characterizing dust that can become airborne (re-intrainment of settled dust that may be the source of continuing air contamination), to
S n o Page 4 of 11 o I
CO
co
NYC-WTC_000250539
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000241970
Draft protocol addressing settled surface dust and airborne materials post-WTC collapse.
15 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
14 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320050
Draft ATSDR/DHAC evaluation of ambient and indoor dust near WTC with asbestos data.
14 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317962
Lab evaluation of residential dust near WTC for asbestos and related contaminants (draft).
14 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250606
DOH page showing page 1 of sampling protocol for WTC residential areas.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
15 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
15 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
15 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302176
Residential impact and WTC area dust sampling discussion in ATSDR/DHAC draft, Oct 2001.
14 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304431
Draft ATSDR/DHAC update on ambient environmental monitoring near WTC; area restrictions noted.
14 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
14 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153247
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
14 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434468
Foreword/protocol for ambient/dust evaluation in 30 residential buildings post-WTC.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434214
Overview of residential building dust/air sampling protocol post-9/11; alignment with DOH/EPA/OSH.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250451
Final draft of ambient and indoor dust evaluation protocol for WTC area.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196150
Guidance document discussing the application of the 1 percent asbestos threshold rule for debris cleanup at Ground Zero.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178091
Sampling protocol developed to assess residential exposure to airborne and settled dust near the World Trade Center.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000241970
Draft protocol addressing settled surface dust and airborne materials post-WTC collapse.
Similar indexed content
NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
Similar indexed content
NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
Similar indexed content
NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
Similar indexed content
NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
Similar indexed content