Mr. Bernard P. Orlan December 12, 2001 Air Sampling for Hydrocarbons & Metals Page 2 P. S. 234fManhattan) ATC Project No. 15-19125-0279

The established regulatory values for HCs and metals are intended for industrial workplace exposures and are not generally applicable to office/school settings. There are no standards for hydrocarbon vapors or metals for indoor air in non-industrial situations.

HYDROCARBON RESULTS

Each sample was analyzed for the following sixteen hydrocarbon (HC) compounds: Pentane, Acetone, Methylene chloride. Hexane, Chloroform, Methyl chloroform. Total Other A Hydrocarbons, Benzene, 1, 2-Dichloroethane, Trichloroethylene, Toluene, Perchloroethylene (tetrachloroethylene), Chlorobenzene, Ethylbenzene, Styrene, Cumene (isopropylbenzene). Xylenes, Total Other B Hydrocarbons. The limit of detection for each compound was 0.020 milligrams per sample. The airborne concentrations were calculated by dividing the amount found in the sample by the volume of air collected and converting the quotient to parts per million (ppm).

The HC present above the limits of detection were the Total Other B Hydrocarbons which were found in all three indoor samples collected on November 29“’ (range: 0.095 - 0.322 ppm) and 30“’ (range: 0.780 - 5.00 ppm). In one sample collected on November 30“’, tetrachloroethylene (0.036 ppm), ethylbenzene (0.061 ppm) and xylenes (0.294 ppm) were detected. In one sample collected on December 1®*, contained tetrachloroethylenelO.346 ppm), chlorobenzene (0.129 ppm), ethylbenzene (0.154 ppm), styrene (0.076 ppm), xylene (0.859 ppm) and total other B hydrocarbons (16.6 ppm). (As stated previously, total B hydrocarbons include petroleum naphtha and mineral spirits which are common components of paint). These levels corresponded with the highest real-time TVOC readings. Xylenes and other B hydrocarbons were also detected in the two other indoor samples from that date. These compounds were not detected in the roof sample. The custodial staff was painting in various areas inside the school during the sampling period and a strong paint odor was detected by ATC. Real-time measurements for total volatile organic compounds made during the same time period were as high as 21 ppm (Dec. 1). Only total other B hydrocarbons were detected (0.158-0.301 ppm) in the indoor samples from December 2"“. The paint odor had dissipated substantially on that date.

METAL SAMPLE RESULTS

Each sample was analyzed for aluminum, cadmium, chromium, cobalt, copper, iron, magnesium, manganese, molybdenum, nickel and zinc. The limits of detection ranged from less than 0.0001 milligrams per sample (mg/sample) for nickel, copper, cobalt and cadmium to 0.001 mg/sample for iron and molybdenum. The airborne concentrations were calculated by dividing the amount found in the sample by the volume of air collected.

Chromium were detected in all samples however it was detected in the blanks from both days. When the chromium level in the blank is subtracted from the amount in the samples, the airborne concentrations drop below the limit of detection. Any chromium detected was already in the filter and did not come from the ambient air. On November 29*, trace amounts of iron and copper were found in the roof sample only. Iron was found in one indoor sample (0.001 mg/m’) and in the outdoor sample (0.002 mg/m^) on November 30* and outdoors (0.001 mg/m^) on December 2"“. Aluminum was detected in two indoor samples and the outdoor sample from December 2”“, however as was the case with chromium, the same amount was found in the blank. The actual airborne concentration was below the limit of detection.

CONFIDENTIAL, CITY_21MC100_003444824 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000249535

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000249535Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000310045

Air sampling report for hydrocarbons, mercury, metals and silica at PS 89M; DOE requested quality verification.

Similar indexed content

Compare copies and versions →