NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan , January 8,2003
Air Sampling for Hydrocarbons, Metals, Mercury & Silica Page 3
P. S. 89(Manhattan)ATC Proiect No. 15-19125-0297
This is not an unusual situation especially during custodial cleaning of the school which
had been conducted around the time these samples were collected during the winter
break.
The likely sources were cleaning materials or disinfectants containing some alcohols.
No other hydrocarbons were found above the limits of detection in any of the samples
collected.
METAL SAMPLE RESULTS
Metal samples were analyzed for aluminum, cadmium, chromium, cobalt, copper, iron,
magnesium, manganese, molybdenum, nickel and zinc. The limits of detection ranged
from less than 0.0001 milligrams per sample (mg/sample) for cobalt to 0.002 mg/sample
for iron. The airborne concentrations were calculated by dividing the amount found in
the sample by the volume of air collected.
Chromium was detected in all samples however it was also detected in both blanks.
When the average chromium level in the blanks is subtracted from the amounts in the
samples, the airborne concentrations drop below the limits of detection. Any chromium
detected were already in the filter and did not come from the ambient air. Zinc was
detected in both blanks but not in any air samples, indicating that zinc may be a random
contaminant of the filter medium.
The Environmental Protection Agency (EPA) has set a screening level for hexavalent
chromium (the more toxic form) in air of 0.6 micrograms per cubic meter of air (ug/m^),
this assumes a continuous exposure for one year. These samples were analyzed for total
chromium (trivalent and hexavalent). All Cr concentrations detected in the samples
higher than the average of the two blanks were below the EPA screening level.
The EPA has no standard or screening level for zinc in ambient air.
MERCURY SAMPLE RESULTS
Mercury was detected in these samples at levels that were indistinguishable from that
detected in the blank.
The established regulatory value for mercury (OSHA: O.lmg/m^) is intended for
industrial workplace exp.osures and is not generally applicable to office/school settings.
There are no standards for mercury in indoor air in non-industri al situations. The EPA
has no standard or guideline for mercury vapor in ambient air.
CITY_21MC100_003057881
NYC-WTC_000309994
OCR can misread numbers and units. Confirm readings against the page image before using them.