NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax' 612- 607-6444
/
Client - ATC
Client's Sample ID ATC-1220-89M-DX8
Lab Sample ID 103233961
Filename F11228B_10
Injected By BAL
- - Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 12/20/2001
ICAL Date 11/19/2001 Received 12/21/2001
CCal Filename(s) F11228B_01 & F11228B_16 Extracted 12/23/2001
Method Blank ID BLANK-1389 Analyzed 12/29/2001 04:50
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF ND 0.0041 A 2,3,7,8-TCDF-13C 2.00 61
Total TCDF 0.038 0.0020 2,3,7,8-TCDD-13C 2.00 74
1,2,3,7,8-PeCDF-13C 2.00 64
2,3,7,8-TCDD ND 0.0023 A 2,3,4,7,8-PeCDF-13C 2.00 64
Total TCDD 0.048 0.0020 1,2,3,7,8-PeCDD-13C 2.00 78
1,2,3,4,7,8-HxCDF-13C 2.00 78
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 68
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6.7,8-HxCDF-13C 2.00 75
Total PeCDF 0.013 0.0100 J 1,2,3,7,8,9-HxCDF-13C 2.00 73
1,2,3,4,7.8-HxCDD-13C 2.00 104
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6.7,8-HxCDD-13C 2.00 80
Total PeCDD 0.026 0.0100 J 1,2,3,4.6,7,8-HpCDF-13C 2.00 75
1.2,3,4,7.8,9-HpCDF-1.3C 2.00 74
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7.8-HpCDD-13C 2.00 88
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 69
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
‘ t
Total HxCDF 0.017 0.0100 J 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1.2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37Cl4 0.20 73
1,2,3,6,7,8-HxCDD ND 0.0100
a 1,2,3,7,8,9-HxCDD
Total HxCDD
ND
0.064
0.0100
0.0100
1,2,3,4,6,7,8-HpCDF 0.017 0.0100 J Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.0011 ng/m2
Total HpCDF 0.031 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.055 0.0100
Total HpCDD 0.100 0.0100 J
OCDF 0.026 0.0200 J
OCDD 0.390 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substitut6d isomers) 1 = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ’ = See Discussion
Report No.... 01-1052540
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003474165
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000249281