NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
we Analytical__________ Method 8290 Analysis Results
Tsi; 612-607-1700
Fa>L612_60A644E
Client - ATC
Client's Sample ID ATC-1220-89M-DX7
Lab Sample ID 103233953
Filename F11228B_09
a Injected By BAL
Matrix WIPE
Total Amount Extracted 1 m2
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 12/20/2001
I CAL Date 11/19/2001 Received 12/21/2001
CCal Filename(s) F11228B_01 & F11228B_16 Extracted 12/23/2001
Method Blank ID BLANK-1389 Analyzed 12/29/2001 04:00
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF ND 0.0020 2,3,7,8-TCDF-13C 2.00 56
I Total TCDF
2,3,7,8-TCDD
0.0098
ND
0.0020 J
0.0020
2,3,7,8-TCDD-13C
1,2,3,7,8-PeCDF-13C
2,3,4,7,8-PeCDF~13C
2.00
2.00
2.00
69
61
60
Total TCDD 0.0310 0.0020 1,2,3,7,8-PeCDD-13C 2.00 74
1,2,3,4,7,8-HxCDF-13C 2.00 67
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 65
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 67
?J
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 66
1,2,3,4,7,8-HxCDD-13C 2.00 96
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 70
Total PeCDD 0.0160 0.0100 J 1,2,3,4,6,7,8-HpCDF-13C 2.00 69
1,2,3,4,7,8,9-HpCDF-13C 2.00 69
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 84
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 64
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
i Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 70
a 1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
Total HxCDD
ND
ND
0.0260
0.0100
0.0100
0.0100 J
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00038 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0220 0.0100 J
3 Total HpCDD 0.0410 0.0100 J
OCDF ND 0.0200
OCDD 0.1600 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,S-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ’ = See Discussion
Report No.... 01-1052540
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Ino.
CONFIDENTIAL, CITY_21MC100_003474164
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000249280
OCR can misread numbers and units. Confirm readings against the page image before using them.